ADC Release 3.1 User Manual page 360

Release 3.1 gui
Table of Contents

Advertisement

1152700 Issue 1 February 2001 Operation and Maintenance
DLP-782
Page 1 of 6
REBOOTING THE SYSTEM USING A SAVED OR DEFAULT DATABASE
Summary: The following procedure defines the steps required to reboot the system using the
database files previously stored from the NMIC, or clearing all existing database files and
restarting the system from scratch. The database files can be used to restore a system if a
catastrophic failure occurs and database corruption is imminent. Refer to DLP-745 for
procedural information on saving the existing database. Section A below steps the user through
the process of FTP'ing remote files to a tmp directory on the NMIC and rebooting using these
files. Section B steps the user through the process of rebooting the system using a backup
database previously stored on the NMIC in the config directory. For rebooting using the default
system database and rediscovering the system from scratch go to section C below.
A. FTP REMOTE DATABASE FILES TO THE NMIC AND REBOOT THE SYSTEM
1. Telnet to the standby NMIC using the NMIC specific IP address.
2. Execute the following command to stop all processes running on the standby NMIC.
killall psm
3. Execute the following command to force the NMIC processes to die.
killall -9 nmic ftpClnt
4. Telnet to the active NMIC using the NMIC specific IP address.
5. Execute the following command to stop all processes running on active NMIC.
killall psm
6. Execute the following command to force the active NMIC processes to die.
killall -9 nmic ftpClnt
7. Enter the following command to change to the directory where the database files are stored
on the active NMIC.
cd /cellworx/config
8. Enter the following command to save off the corrupted NMIC db in case it is needed later:
mv NMIC NMIC.corrupted
9. Enter "exit" to return to a DOS prompt.
10. FTP to the NMIC by entering the following command at the DOS prompt:
ftp <active NMIC IP address>
Page 2-340
© 2000, ADC Telecommunications, Inc.