Commissioning
4.11 Configuring brake control
4.11.3

Extended brake control

4.11.3.1

Basics

Requirement
● The "Extended brake control" function module is activated (see Section "Function
modules (Page 182)").
Description
The "Extended brake control" allows complex brake controls, such as for motor holding
brakes and service brakes. The brake is controlled in the following manner. The order
represents the priority:
● Via parameter p1215
● Via binectors p1219[0...3] and p0855
● Via standstill detection
● Via the connector connection threshold
Features
● Forced brake opening (p0855, p1215)
● Closing of brake for a 1 signal "unconditionally close holding brake" (p0858)
● Binector inputs for opening or closing the brake (p1218, p1219)
● Connector input for the threshold for opening and closing the brake (p1220)
● OR/AND block each with two inputs (p1279, r1229.10, r1229.11)
● Holding and service brakes can be activated
● Monitoring of the brake feedback signals (r1229.4, r1229.5)
● Configurable responses (A07931, A07932)
● Closing of brake after the "Enable speed controller" signal has been canceled (p0856)