Appendix
A.3 Temperature sensors for SINAMICS components
Component
TM150
SME20
SME120/SME125
Active Line Module
Smart Line Module
380
Interface
Pin
X531
1
2
3
4
X532
1
2
3
4
X533
1
2
3
4
X534
1
2
3
4
X535
1
2
3
4
X536
1
2
3
4
Measuring system
7
interface
9
X200 (connector)
1
Temperature chan-
2
nel 2
X200 (connector)
3
Temperature chan-
4
nel 3
X200 (connector)
5
Temperature chan-
6
nel 4
Booksize
1
X21 (terminal)
2
Chassis
4
X41 (terminal)
3
Booksize
1
X21 (terminal)
2
Chassis
4
X41 (terminal)
3
Signal name
Technical specifications
+Temp
KTY84-1C130/PTC/bimetallic NC
-Temp
contact/PT100/PT1000
+Temp
Information on interconnecting the
-Temp
temperature channels can be
found below
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
+Temp
-Temp
-Temp
Temperature sensor
+Temp
KTY84-1C130 / PTC
connection cable with article num-
ber 6FX8002-2CA88-.... neces-
sary
-Temp
Temperature sensor
+Temp
KTY84-
1C130/PTC/PT1000/bimetallic
switch with NC contact
+Temp
Temperature sensor
-Temp
KTY84-
1C130/PTC/PT1000/bimetallic
switch with NC contact
+Temp
Temperature sensor
-Temp
KTY84-
1C130/PTC/PT1000/bimetallic
switch with NC contact
+Temp
Active Line Module temperature
-Temp
sensor
Temperature switch type: bimetal-
+Temp
lic switch with NC contact
-Temp
+Temp
Active Line Module temperature
-Temp
sensor
Temperature switch type: bimetal-
+Temp
lic switch with NC contact
-Temp
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1