Parameter View - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

2.3.5

Parameter view

The "Parameter view" (expert list) provides a clearly organized display of the parameters
available for the device.
Note
Locked parameters
None of the parameters with the padlock icon can be changed OFFLINE. To enter these
parameters offline, use the appropriate screen forms and dialogs in the hardware
configuration that you find in the device view.
The following figure shows the structure of the parameter view:
Drop-down list to restrict the parameter views: Standard, Extended, Service
Parameter number
Parameter name
Button for comparing the parameters of the drive object to another parameter set. "Online", "Offline", and "Factory
setting" can be compared.
Icon for starting a CSV export.
Icon to retentively save the parameters (Copy RAM to ROM)
Icon to restore the factory settings.
Icon to display invalid BICO interconnections.
Value of the parameter
Unit
Data set:
Indicates the data set (MDS, DDS, etc.) to which the parameter belongs.
Minimum value
Maximum value
Figure 2-7
Parameter list
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Startdrive commissioning tool
2.3 User interface - parameterization