7. If you also want to acquire the optional motor data and circuit diagram data, activate the
"Activate the display of the ..." options in the "Rating plate values" screen form.
The additionally activated subareas are displayed in the secondary navigation under
"Motor details".
Figure 4-34
8. Acquire the required motor data of the inserted motor.
The pink input fields are mandatory input fields. If appropriate values are not entered in
these fields, the device configuration cannot be completed.
Result
The motor is specified with the manually acquired motor data. The white area turns dark
gray.
If you have selected a motor with encoder, the encoder and the encoder evaluation are also
added automatically.
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Motor specified
4.4 Creating a project offline in Startdrive