Infeed Unit; Overview - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning
4.7 Basic parameterization of the drive objects
4.7.2

Infeed unit

4.7.2.1

Overview

Infeed units (Line Modules)
Line Modules contain the central line infeed for the DC link. Various Line Modules can be
selected to address the various application profiles:
● Basic Line Modules (BLM)
● Smart Line Modules (SLM)
● Active Line Modules (ALM)
Basic parameterization of the infeed unit
Define the following data in the basic parameterization of the infeed unit:
● Function modules
● Line data/operating mode
● Enable logic
● Line contactor control
Calling the screen form
1. In the project navigation, select menu "Infeed_x > Parameter".
The corresponding detailed view is displayed at the right.
2. In the secondary navigation, call menu "Basic parameterization > xxx" (xxx stands for the
name of the particular detailed screen form).
The detailed view is updated.
174
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1