9.2.9

Control Unit: Infeed operation (BICO interconnection)

Execution
Digital inputs
Bidirectional digital inputs/outputs
1
X132
Output
DO 12
7
Input
DO 13
8
10:1
Infeed
Control_Unit
r807: Bit0, BO: Master control active: : Master control active (1=Yes/0=No)
r863: Bit0, CO/BO: Drive coupling status/control word: : Infeed operation (1=Yes/0=No)
r863: Bit1, CO/BO: Drive coupling status/control word: : Control line contactor (1=Yes/0=No)
© Siemens AG 2007 All Rights Reserved
SINUMERIK 840Di sl Manual (HBIsl) – 01/2007 Edition
To output the "Infeed operation" signal at terminal X132.7 of the Control Unit,
parameter: "r863 Bit 0" of the infeed must be connected to parameter: "p742" of
the Control Unit via BICO interconnection:
S
Infeed: r863 Bit 0: Infeed operation
S
Control Unit: p742, BI: CU signal source for terminal DI/DO 12
and terminal X132.7 of the Control Unit must then be parameterized as output
DO12.
Perform the following actions:
1. Double–click Project > Drive_Unit_Addr10 > Control Unit > Inputs/Outputs
to open the terminal configuration in the project navigator.
2. In the "Bidirectional digital inputs/outputs" tab (1), change the status for ter-
minal X132.7 to "Output" (2)
3. Click the binector input symbol of terminal X132.7, DO12 (3) and select the
signal: Infeed > "r863: Bit0, ... Infeed operation" (4).
Measuring sockets
Invert output
2
9 Drive Commissioning (SINAMICS)
9.2 ONLINE commissioning
0
0
1
0
Control_Unit
Drive_1
Drive_2
Drive_3
Close
Infeed
Further interconnections...
1
3
1
Help
4