Siemens SIMATIC IPC1047 Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC1047:
Table of Contents

Advertisement

Quick Links

SIMATIC IPC1047
SIMATIC
Industrial PC
SIMATIC IPC1047
Operating Instructions
07/2019
A5E45118479-AB
Preface
Overview
Safety Instructions
Installing and connecting the
device
Commissioning the device
Operating the device
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Dimension drawings
Standards and approvals
Technical support
Markings and symbols
Abbreviations
1
2
3
4
5
6
7
8
9
10
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC1047

  • Page 1 SIMATIC IPC1047 Preface Overview SIMATIC Safety Instructions Installing and connecting the device Industrial PC SIMATIC IPC1047 Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications Dimension drawings Standards and approvals...
  • Page 2: Safety Instructions

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    A solid background in electrical installation, personal computers, Microsoft operating systems and network technology is required to understand this manual. Validity of the Operating Instructions These operating instructions are valid for all supplied versions of the SIMATIC IPC1047. Scope of this documentation The documentation for the SIMATIC IPC1047 includes: ●...
  • Page 4: Commissioning The Device

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 5: Table Of Contents

    Connecting I/O devices ......................36 Commissioning the device ........................37 General information on commissioning .................. 37 Switching on the device ......................38 Automatic switching on of the device ..................39 Switching off the device ......................39 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 6 Installing the PCI expansion kit (optional) ................74 6.3.5 Removing and installing the graphics card ................76 6.3.6 Installing and configuring the hardware RAID adapter card ..........78 Installing a second COM interface (optional) ................. 80 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 7 Service and support ......................113 Troubleshooting ........................114 A.2.1 Problems with device functions .................... 114 A.2.2 Problems with the RAID system and device startup ............. 115 A.2.3 Problems when using expansion cards ................116 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 8 Table of contents Markings and symbols ......................... 117 Overview ..........................117 Safety ........................... 117 Operator controls ......................... 118 Certificates, approvals and markings ................... 117 Interfaces ..........................118 Abbreviations ............................119 Glossary .............................. 125 Index ..............................133 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 9: Overview

    Overview Product description 1.1.1 Overview The SIMATIC IPC1047 is a high-performance rack PC with industrial functionality: ● Highly compact ● Extremely rugged ● Extensive product continuity Note Depending on the configuration ordered, the features and illustrations described in this manual may differ from the features of your device.
  • Page 10: Highlights

    – "Zero-Maintenance Cache Protection" protects the data in the hardware RAID controller cache in the event of a power failure – Reduced load on the main processor during the rebuild – Fast HDDs/SSDs for high speed when reading and writing data SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 11: Features

    POWER (internal power supply present, PC switched on) • HDD (access to hard disk) • FAN FAIL (display fan problems) • Power supply status, Monitoring of redundant power supply (optional) power, temperatures, voltages SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 12 Backup for data reliability in the event of power failures LAN expansion card Intel® I350-T2, 2 × 1 GB LAN • Intel® I350-T4, 4 × 1 GB LAN • Intel® X540-T2, 2 × 10 GB LAN • SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 13: Design Of The Device

    ● Drive cage type A with slots for removable drives The removable trays can be locked; this way, the drives are protected from unauthorized access. ● Drive cage type B with fixed slots for drives SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 14: Rear Of The Device

    Rear view with AC power supply ① ⑤ ATX power supply Interfaces ② ⑥ Power LED Expansion card slots ③ ⑦ On/off switch PCI expansion kit interface (optional) ④ ⑧ Power connection socket 2nd COM interface (optional) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 15: Interfaces At Rear Of The Device

    Interfaces at rear of the device ① COM interface ② RJ45 IPMI dedicated LAN connection ③ USB 2.0 ports ④ USB 3.0 ports ⑤ Gbit ETHERNET interface 1 ⑥ Gbit ETHERNET interface 2 ⑦ VGA connection SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 16: Status Displays

    PC in operation Access to hard disk No access GREEN Access FAN FAIL Fan status No error RED flashing Possible causes: CPU heat sink fan fault • Front fan faulty • Power supply fan fault • SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 17: Power Indicators, Redundant Power Supply

    ① The following figure shows an example with power supply module in operation and power ② supply module out of service. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 18 GREEN Power supply module 2 in operation • PC switched on • Flashes RED Power supply 2 interrupted Power supply module 2 defective Flashes slowly Warning at power supply module 2, RED/GREEN e.g. overload SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 19: Status Displays On Removable Tray For Drives

    Power supply not connected • No drive installed • Device is switched on and a drive is • installed Activity Status of the drive Flashes Drive is active • Drive is not active • SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 20: Accessories And Spare Parts

    Overview 1.3 Accessories and spare parts Accessories and spare parts Accessories from Siemens are available for your device. These are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall You can find additional information in the online ordering system Industry Mall (https://mall.industry.siemens.com).
  • Page 21: Safety Instructions

    • For control cabinet installation: Use a central, easily accessible AC circuit breaker close to the device, if possible. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 22 Electrostatic sensitive devices (ESD) The device contains electronic components that may be destroyed by electrostatic charges. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures when you open the device. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 23 This may cause the device, machine or plant to malfunction. • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 24 Fire protection enclosure Note The device meets the requirements for fire protection enclosures in accordance with IEC/EN/UL 61010-2-201. It can therefore be installed without an additional fire protection cover. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 25 Touching these areas or components can cause death or serious physical injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 26: Notes On Ambient And Environmental Conditions

    ● You can install the device without an additional fire protection enclosure. It meets the requirements for fire protection enclosures in accordance with IEC/EN/UL 61010-2-201. ● Ensure that the installation opening for the device is splash-proof in areas which may be subject to splash water. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 27 Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 28 ● UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". ● We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 29: Installing And Connecting The Device

    The device can be clearly identified with the help of this identification data in case of repairs or theft. Make note of identification data Enter the following data in the table below: Serial number SVP... Order no. 6BK... Microsoft Windows Product Key SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 30: Permitted Mounting Positions

    The device can be installed horizontally in consoles, control cabinets and 19" rack systems. NOTICE Operation in closed rooms The device is approved for operation in closed rooms only. Pay attention to the ambient and environmental conditions. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 31: Mounting The Device

    • Secure the device additionally using cabinet brackets, telescopic rails or a device base. The mounting screws of the telescopic rails may not protrude more than 5 mm into the device. • Use the brackets on the front panel to carry and lift the unit. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 32: Mounting The Device

    ③ Manufacturer Schroff, article number type 20110-072 The telescopic rails are secured with M4 screws. The dimensions for the associated mounting holes are listed in the section "Dimension drawing for telescope rails (Page 110)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 33: Connecting The Device

    The power supply cord and the plug connector must bear the prescribed markings. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 34: Connecting The Power Supply

    ● You have observed the Information about the power supply (Page 34). ● The connecting cables, connectors, sockets and connection materials used meet the requirements according to section "Country-specific information on supply voltage (Page 33)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 35: Connecting A Redundant Power Supply

    Note If only one power supply module is switched on or connected, or a module is defective, a warning signal is emitted. The warning signal stops when the acknowledgment button is pressed. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 36: Connecting I/O Devices

    1. Connect the I/O devices to the respective interfaces. Information on the position of the interfaces is available in "Interfaces at rear of the device (Page 15)". 2. Secure the cables with strain relief, if necessary. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 37: Commissioning The Device

    ● An operating system is installed. The device can be supplied without an operating system. You can find additional information on installation of the operating system in the section "Installing the software (Page 91)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 38: Switching On The Device

    The product key is located on the "Certificate of Authenticity" in the "Product Key" line, see section "Identification data of the device (Page 29)". Result The interface of the operating system is displayed every time you turn on the device and after the startup routine. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 39: Automatic Switching On Of The Device

    For non-Windows operating systems: ● Briefly press the on/off button. The operating system is shut down. The "POWER" LED goes out. The device is switched off but not fully disconnected from the line voltage. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 40 Perform a hardware reset only in the case of an emergency. 1. Press the on/off switch for more than 4 seconds. 2. Alternatively, press the reset button. Information on the position of the buttons is available in the section "Front panel (Page 13)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 41: Operating The Device

    ● 2.5" drives: Maximum 8 (with maximum overall height of 15 mm) ● 3.5" drives: Maximum 4 Hard disks can be connected via SATA or corresponding drives via an additional SAS controller. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 42: Raid Systems

    The safe system states RAID Level, for example, 1 are only reached once synchronization has been successfully completed. In addition, system performance may be limited in the case of a manually started maintenance operation until completion of the maintenance phase. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 43: Raid System Of The Motherboard

    ● For applications with stringent requirements regarding low system disturbances of the RAID system. ● With maintenance-free battery backup for high data reliability. ● The RAID controller with PCIe x8 interface occupies one PCIe x8 or x16 expansion slot of the device. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 44 The 4-port or 8-port variant can be used. An optionally available hot-spare drive can further increase the availability of the system. ① Connection for the SAS/SATA data cable ② Connection for Zero Maintenance Module (ZMM) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 45: Raid1 System

    You can find additional information in chapter "Manage onboard RAID system (Page 46)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 46: Operating Raid Systems

    "UEFI Boot Type in the "Boot" menu in the BIOS setup, the RAID hardware is configured by using the "Device Management" button in the BIOS selection menu. 5.3.1.1 Example for a RAID1 system during the boot phase of the system SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 47: Raid Software

    Execution of keyboard, mouse or touch screen commands may be briefly delayed in extreme situations. This could result in operator errors on the machine or plant. Do not operate safety-critical functions when a hard disk has failed. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 48: Displaying A Defective Hard Disk Of A Raid System In The Raid Software

    BIOS setup menu "Boot". Otherwise, the system will boot from the hard disk you have just installed and the message "Operating system not found" will be displayed. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 49: Integrating A New Hard Disk Drive In The Raid System

    Sequence The following figure is an example for the automatic rebuilding process. A defective hard disk is still displayed during the rebuilding process. This display disappears when the rebuilding process is completed. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 50: Managing The Hardware Raid System

    The status of the RAID system is displayed via the Adaptec controller. Additional software is not required. Additional information is available in the sections "RAID systems (Page 42)" and "Installing and configuring the hardware RAID adapter card (Page 78)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 51: Monitoring Functions

    ● Power management with remote switch-on and switch-off of system ● System access at BIOS level ● Integration of virtual media, e.g. installation medium ● Event display with logging ● KVM console (KVM-Over-IP for Video Redirection) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 52: Trusted Platform Module (Tpm)

    The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 53: Expanding And Assigning Parameters To The Device

    ● The device is fully disconnected from the line voltage, see section "Switching off the device (Page 39)". ● All connecting cables are unplugged ● The front door is open; see section "Opening the front door (Page 41)". ● Tx10 screwdriver SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 54: Drives

    Drives in drive cage type A The following applies to devices with drive cage type A: ● Maximum configuration: 4 × 3.5" or 2.5" drives in removable drive bay ● Permissible operating temperature range: 0 ... 40 °C SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 55 ① Drive in drive bay for internal, robust installation ② Drive type "SATA" or "SAS" is possible With maximum overall height of 15 mm Restriction: A maximum of 40°C is permissible with SAS drives. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 56: Drives In Drive Cage Type A

    ● If there is no RAID system: The device is fully disconnected from the line voltage, see section "Switching off the device (Page 39)". ● The device you wish to replace is inactive. ● When replacing an HD: T10 screwdriver ● When replacing an SSD: T8 screwdriver SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 57 Ensure that the removable tray fits tightly in the drive cage. 10.Close the tray bracket. 11.Lock the removable tray with the key. Note The removable tray must always be locked to ensure reliable operation of the devices with removable trays. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 58: Installing A 5.25" Adapter Module For Removable Trays

    1. Unlock the drive mounting bar together with the blanking plate by pressing laterally ① against the surfaces and push the drive mounting bar forward from the device in the direction of the arrow. 2. Remove the blanking plate. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 59: Installing A Backplane For Removable Tray

    "Accessories and spare parts (Page 20)". ● The device is fully disconnected from the line voltage, see section "Switching off the device (Page 39)". ● The device is open; see section "Open the device. (Page 53)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 60 4. Remove the blanking plates which may be located to the right of the cover at the front of the drive cage. 5. Remove all existing removable trays until the drive cage is freely accessible. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 61: Changing A Backplane For Removable Tray

    The backplane is installed from inside at the back end of the drive cage type A and is equipped with interfaces for data cable to the motherboard. This enables the convenient connection of the data cables from the motherboard to the drive in the removable tray at these interfaces. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 62 ④ 3. Remove the unlatched backplane board by turning it upwards from the brackets and removing it from the drive cage. See also Installing a backplane for removable tray (Page 59) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 63: Drives In Drive Cage Type B

    ● Tray 2: 2 × 2.5" drives, horizontal format ● Tray 1: 1 × 2.5" drive, vertical format Additional mounting location: An additional hard disk drive can be installed between the top mounting location and the enclosure wall. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 64 – 2 × 2.5" – 2 × 2.5" – 2 × 2.5" – 2 × 2.5" ● Mixed installation: – 1 × 3.5" – 1 × 3.5" – 1 × 2.5" – 1 × 2.5" SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 65: Removing And Installing A Tray From/In The Drive Cage

    3. Place the tray on the mounting base. Installation Proceed in the reverse order for the installation. Ensure that the tray latches in the bottom of the drive cage. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 66: Removing And Installing 3.5" Drives From/In Tray

    2. Pull the two guides of the tray outwardly until the marked nipples release the drive. 3. Only touch the sides of the drive. 4. Remove the drive by lifting it upwards, and place it carefully on the mounting base next to the tray. Installation Proceed in reverse order. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 67: Removing And Installing 2.5" Drives From/In Tray

    In the following figure, the installation in vertical format is shown on the left and the installation in horizontal format on the right. 2. Unscrew the highlighted screws. 3. Lift up the tray and place it on the mounting base next to the drive. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 68 Ensure that each hole of the tray is positioned exactly over the threads of the drive. 4. Screw on the drive from behind. Do not tighten the screws too much. Do not exceed the maximum tightening torque of 0.7 Nm. Installation in vertical format SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 69 ● For installation in vertical format, the drive lies inside the tray. ● For installation in horizontal format, the drive lies outside on the tray. ● For installation in horizontal format, you can mount two drives one above the other. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 70: Replacing A Defective Hard Disk Drive In The Raid System

    3. Replace the defective hard disk with a hard disk of the same type and capacity. See also Drives in drive cage type A (Page 56) Drives in drive cage type B (Page 63) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 71: Expansion Cards

    In the case of long PCI/PCIe expansion cards, connections on the motherboard can become hidden. Note on PCI Express expansion cards An expansion card or graphics card can occupy two slots in each case. See also Dimension drawing of the expansion cards (Page 110) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 72: Configuration Variants

    Basic configuration without expansion cards Temperature range 0 °C to 40 °C (maximum configuration) Expansion up to 6 expansion cards: The maximum total power loss of all expansion cards is 200 W. Maximum permitted configuration SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 73: Installing And Removing Expansion Cards

    3. Secure the expansion card with the corresponding screw. Removal Proceed in the reverse order for the removal. In step 2, unlock the expansion card in the slot before removing it. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 74: Installing The Pci Expansion Kit (Optional)

    6.3.4 Installing the PCI expansion kit (optional) Requirement The PCI expansion kit consists of the following components: ● Card retainer ● Fixing pins and screws ● Riser card with slot for PCI expansion card SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 75 5. Press the outside of the guide rail bracket against the locking element and screw it in place, as shown. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 76: Removing And Installing The Graphics Card

    • Wait until the fan blades come to a standstill. • Only then should you remove the graphics card. Removal 1. Remove the two screws ① the expansion card. Also remove the two screws of ③ the card retainer on the outside. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 77 Proceed in the reverse order for the installation of the graphics card. In step 3, push the card retainer fully forward and downward onto the support adapter. Ensure that the support adapter is fully inserted into the groove of the card retainer as shown. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 78: Installing And Configuring The Hardware Raid Adapter Card

    ● The hardware RAID adapter card with connection for the SAS/SATA data cable ② connection for the capacitor block of the ZMM ① ● An adapter cable for connection of the hard disk drive to the RAID module ② Observe the numbering of the connections SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 79 EFI boot medium is available, you must press the <ENTER> key after having pressed the <CTRL+A> within 1 second. The system starts if you do not press the <ENTER> key in time. 3. Assign the parameters under "Controller Configuration" as follows: SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 80: Installing A Second Com Interface (Optional)

    3. Insert the slot bracket with the pin connector of the COM interface and screw it in place. 4. Insert the plug connector onto the marked location on the motherboard. No other steps are needed for installing the COM interface. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 81: Device Maintenance And Repair

    ● UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". ● We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 82: Maintenance Intervals

    1. Open the front door until the marked lock releases the fan cover, see also section "Opening the front door (Page 41)". 2. Take hold of the recessed grip. 3. Open the fan cover in the direction of the arrow. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 83: Replacing Filters

    ● The device is fully disconnected from the line voltage, see section "Switching off the device (Page 39)". ● The device is open; see section "Open the device. (Page 53)". ● 1 fan, article number 6BK1700-6HA71-0AA0 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 84 1. Detach the plug of the connecting cable of the fan from the mother- board. 2. Detach the protective grille from the device fan. 3. Lift the device fan in the marked keyhole and remove it towards the front. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 85: Change The Fan On Drive Cage Type A

    ● The adapter module for removable drive trays is removed, see section "Installing a 5.25" adapter module for removable trays (Page 58)". ● An original spare part, i.e. a fan of the same type. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 86 6. Guide the fan cable through the cable outlet ② 7. Finally, snap the new fan completely into place in the locking latches 8. Mount the fan support on the drive cage (see above). 9. Connect the fan cable to the motherboard. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 87: Replacing The Backup Battery

    • Do not touch any adjacent modules. NOTICE Damage to the battery Grease residues from your hands damage the battery. • Do not touch the battery with your hands. • Use suitable gloves, for example. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 88 ● Close the device as specified in section "Open the device. (Page 53)". ● Set the BIOS setup. The configuration data of the device may be deleted after a battery replacement depending on the BIOS setup setting. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 89: Replacing The Redundant Power Supply Module

    6. Slide the new power supply module into the frame all the way to the rear until it clicks into place. ② 7. Reconnect the power plug Alternatively, restart the device. ① ④ Both LEDs light in green again. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 90: Replacing The Processor

    Information about original spare parts for SIMATIC IPCs is available on the Internet at: – Contacts (http://www.siemens.com/automation/partner) – SIMATIC IPC after-sales information system (http://www.siemens.com/asis) Procedure 1. Remove the screws on the CPU heat sink. 2. Remove the heat sink.
  • Page 91: Installing The Software

    All data on drive C: will be completely deleted, reformatted and overwritten with the original factory software. If "Restore entire drive" is set ALL data, user settings, authorizations or license keys will be lost on the entire drive. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 92: Restoring The Factory Settings Of The Operating System And Partitions (Restore)

    The Restore function restores the volume partitions, the operating system with installed device drivers, and the SIEMENS software products. Before performing the Restore function, observe the information in section "Back-up authorization or license key (Page 91)". Setting Boot mode...
  • Page 93: Updating The Operating System

    3. Boot with the provided USB stick in the Boot mode you have set beforehand. 4. In the Windows® Boot Manager, select the option "Restore Microsoft Windows ..." and confirm the selection. The Restore program from Siemens starts after a few seconds. 5. Follow the instructions on the screen. Note the following information.
  • Page 94: Installing Drivers And Software

    7.4.5 Installing Windows (Recovery) The recovery function only installs the operating system on your device. In contrast to the restore function, no device drivers and no SIEMENS software products are installed by the recovery function. Note Specific information on using the Windows operating systems is available on the Internet: •...
  • Page 95 The language of the installation program and the operating system is preset to English. You can change the language of the operating system after the installation. Information on this topic is available in the section "Setting up the language selection using the Multilanguage User Interface (MUI)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 96 Please read the information under "Information for systems with RAID or AHCI controller" at the end of this section. Drive options Display of additional functions that you can use to set up the data storage media, (advanced) see the following figure. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 97 Information on how the data medium is partitioned in its factory state is available in the tables below. 2. Select the partition on which you want to install the operating system. 3. Click "Next". Installation is started. The Windows operating system is installed on the data medium. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 98: Installing Hardware Raid Controller Software

    4. Select the respective driver on the USB stick. 7.4.6 Installing Hardware RAID controller software Note Observe the "General information on commissioning (Page 37)" in section "Commissioning the device". Additional information is available in section "Installing drivers and software (Page 94)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 99: Bios Description

    1. Set up the dynamic address assignment via DHCP Alternatively, assign a fixed IP address, e.g. "192.168.10.253". 2. Establish a connection to IPMIView, see section "Monitoring functions (Page 51)". 3. Set up the remote control via iKVM, also with IPMIView. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 100: Recycling And Disposal

    ● Do not dispose the device or its replacement and expansion components in household waste and not at public waste disposal points. ● For environmentally compatible recycling and disposal of the device and its components, contact a certified disposal company for electronic waste or your Siemens contact (product return (https://support.industry.siemens.com/cs/ww/en/view/109479891)). Observe the following: ●...
  • Page 101: Technical Specifications

    IP 30 (front) with closed front door • IP 20 on the rear according to EN 60529 • Dust protection With closed front door Filter class G2 EN 779, 99% of particles > 0.5 mm are filtered SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 102 3 V/m 2...6 GHz, 80% AM 1 kHz, • according to IEC 61000-4-3 10 V, 15 KHz...80 MHz, 80% AM 1 kHz, • according to IEC 61000-4-6 Magnetic field 100 A/m, 50 Hz/60 Hz, according to IEC 61000-4-8 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 103 1000 shocks per axis Operation Half-sine: Acceleration 50 m/s , duration 30 ms Special features Quality assurance In accordance with ISO 9001 Motherboard You can obtain more detailed information from the manufacturer, see section "Motherboard (Page 108)". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 104 Supported RAID level: 0, 1, 5, 10 • Graphics Graphics controller Onboard Aspeed AST2400 400 MHz ARM926EJ 16 KB/16 KB Cache Graphics memory 800 Mbps DDR3/DDR2 SDRAM 16 Bit, 512 MB ECC (optional) PCIe VGA/2D Controller 1920 × 1200@60Hz 32bpp SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 105: Current And Power Requirements

    1 × graphics card NVIDIA QUADRO P1000 3.75 1 × graphics card NVIDIA QUADRO P400 1 × 2.5" SSD SATA (typical) 1 × 2.5" HDD SAS (typical) 0.59 0.37 1 × 3.5" HDD SATA (typical) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 106: Power Supply (Ac)

    SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 107: Ac Power Supply, Redundant

    SIMATIC PCs with an active PFC. UPS characteristics are described and classified in the standards EN 50091-3 and IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are identified with the classification "VFI-SS-.." or "VI-SS-..". SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 108: Motherboard

    Technical specifications 8.5 Motherboard Motherboard You can find more detailed information from the manufacturer at " Supermicro (https://www.supermicro.com/products/motherboard/xeon/c600/x10dri.cfm)". Specifically, the manual for motherboard: X10DRi (https://www.supermicro.com/manuals/motherboard/C606_602/MNL-1491.pdf) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 109: Dimension Drawings

    Dimension drawings Dimensional drawing of the device SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 110: Dimension Drawing For Telescope Rails

    PCIe Example PCIe: Graphics card NVIDIA TESLA 106.68 mm / 4.2" 111.15 mm / 4.38" 110 mm 312 mm / 12.28" 265 mm Single Slot Dual Slot: The card requires two free expansion slots SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 111: Standards And Approvals

    SIMATIC IPC1047 certificates (https://support.industry.siemens.com/cs/ww/en/ps/25596/cert). ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 112 Canada. WEEE Directive The device is low-emission, recyclable and meets the requirements of the WEEE Directive 2012/19/EU on the disposal of waste electrical and electronic equipment. Siemens AG is registered with Stiftung EAR, WEEE-Reg. No. DE 23691322. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 113: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) ●...
  • Page 114: Troubleshooting

    BIOS Setup. 2. Set the time and date in the setup menu. Although the BIOS setting is The backup battery is dead. Replace the backup battery. correct, the time and date are still wrong. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 115: Problems With The Raid System And Device Startup

    After changing the drive, "unused" is System was booted without func- Reboot the system with a functioning drive. indicated for the relevant SATA port tioning drive. The removable drive bay might not be switched on. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 116: Problems When Using Expansion Cards

    PC. If the error no longer occurs, the third- Signal frequencies or signal • party expansion card was the cause of the fault. Replace levels are not adhered to this expansion card with a Siemens card or contact the card Different connector pin as- • supplier. signments If the PC still crashes, contact your technical support team.
  • Page 117: Markings And Symbols

    Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. Approval for India SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 118: Operator Controls

    Line Out LAN interface, not approved for con- Microphone input necting WAN or telephone Serial interface Universal audio jack USB port Headphone output USB 2.0 high-speed port USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 119: Abbreviations

    DDRAM Double Data Random Access Memory Memory chip with high-speed interface DHCP Dynamic Host Configuration Protocol Protocol for configuring IP networks Direct Memory Access Direct memory access Display Port New powerful digital monitor port SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 120 Hibernate Once - Resume Many Hyper-Threading HTML Hyper Text Markup Language Script language for creating Internet pages. HTTP Hypertext Transfer Protocol Protocol for data transfer on the Internet Hardware Hardware Input/Output Data input/output on computers SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 121 National Electrical Manufacturers Associ- Syndicate of manufacturers of electrical components in the USA ation Non Maskable Interrupt Interrupt the processor can not reject NTFS New Techniques File System Secure file system for Windows Optical Disk Drive SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 122 SO-DIMM Small Outline Dual Inline Memory Module Serial over LAN Text-based remote control SafeCard on Motherboard (SOM) Standard Parallel Port Synonym for parallel port SRAM Static Random Access Memory Static RAM Solid State Drive SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 123 Wake on Local Area Network World Wide Web Extended Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. Zero Maintenance Cache Protection Maintenance-free cache unit for saving cache contents Module SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 124 Abbreviations SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 125: Glossary

    Communauté Européene. The CE symbol confirms the conformity of the product with all applicable EC directives such as the EMC Directive. Chipset Located on the motherboard, connects the processor with the RAM, the graphics controller, the PCI bus, and the external interfaces. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 126 RAM modules with and without ECC. EMC directive EU directive for electromagnetic compatibility. Compliance is confirmed by the CE symbol and the EC certificate of conformity. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 127 "Hibernate once - resume many" is a method for fast booting from a single Hibernate file that only needs to be created once. HORM ensures restoration of a uniform, saved system state when booting. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 128 The devices connected to a LAN are called nodes. The purpose of networks is the mutual use of files, printers or other resources. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 129 Legacy USB support Support of USB devices, e.g. mouse, keyboard, on the USB ports without driver. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. Low-voltage directive EC Product Safety Directive relating to the safety of products which are operated on low voltage (50 V AC to 1000 V AC, 70 V DC to 1500 V DC) and not specified in other directives.
  • Page 130 Two power supplies are available in redundant operation: The second power supply ensures the power supply of the device in the event of a failure of the first. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 131 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. Track-At-Once In track-at-once recording, a CD can be written to in bits in several sessions if the CD was not closed. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 132 Zero Maintenance Cache Protection Module is a functional unit of the SAS Raid controller that stores data in the cache of the controller in the case of a voltage failure. This functional unit is maintenance-free. SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 133: Index

    COM interface, (2nd COM interface), 80 Filter, (Filter mat), (Filter pad) Mounting, 80 Filter mat Condensation, 24 Changing, 74 Contents, 29 Filter pad Checking, 29 Changing, 83 CPU, 11 Maintenance interval, 82 Fire protection enclosure, 24 Front view, 13 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 134 LEDs, (Status displays) AC power supply, 107 Legacy mode Power supply Recovery, 94 AC supply voltage, 106 Restore, 92 Processor License key, 91 Removal, 90 Limitation of liability, 28, 81 Processor type, 91 Protection class, 102 SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 135 Microsoft Windows Product Key, 29 Serial number, 29 Slave drive, (Multi-disk system) Slots, 11 Spare parts, 20 X-HDD system, (Multi-disk system) Spare parts services, 20 Status displays, 16 Ethernet interface, 17 Status indicators, (Status displays) SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...
  • Page 136 Index SIMATIC IPC1047 Operating Instructions, 07/2019, A5E45118479-AB...

Table of Contents