Ac Power Supply, Redundant - Siemens SIMATIC IPC1047 Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC1047:
Table of Contents

Advertisement

8.4

AC power supply, redundant

Output voltage
Voltage
+ 12 V
- 12 V
+ 5 V
+ 3.3 V
+ 5 Vaux
The accumulated power of the +5 V and + 3.3 V supply may not exceed 130 W.
1
The input current is:
100 V AC: 10 A
240 V AC: 5 A
The maximum inrush current is for:
115 V AC: 80 A
230 V AC: 40 A
Note
Operation at an uninterruptible power supply (UPS)
The power supply contains an active PFC (Power Factor Correction) circuit to conform to the
EMC guidelines. Uninterruptible AC power systems (UPS) must supply a sinusoidal output
voltage in the normal and buffered mode when used with SIMATIC PCs with an active PFC.
UPS characteristics are described and classified in the standards EN 50091-3 and
IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are
identified with the classification "VFI-SS-...." or "VI-SS-....".
SIMATIC IPC1047
Operating Instructions, 07/2019, A5E45118479-AB
Max. current
58.3 A
0.5 A
20 A
1
20 A
1
3.0 A
Technical specifications
8.4 AC power supply, redundant
Voltage stability
+/-5%
+/- 10%
+/-5%
+/-5%
+/-5%
107