Replacing Filters; Replacing Device Fans - Siemens SIMATIC IPC1047 Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC1047:
Table of Contents

Advertisement

7.3.2

Replacing filters

The filter pad is located behind the fan cover.
Note
You may only use filters of the same type. Information about the original spare parts for
SIMATIC PCs is available in the Internet at SIMATIC IPC after-sales information system
(http://www.siemens.com/asis).
Filter pads are available as a pack of 10 under the article number A5E37019277.
Requirement
● The device is disconnected from the power supply; see section "Switching off the device
(Page 39)".
● The front door is open; see section "Opening the front door (Page 41)".
● The fan cover has been removed; see section "Remove the fan cover (Page 82)".
● A filter pad from the pack of 10 A5E37019277
Procedure
1. Remove the filter pad from the fan cover.
2. Insert the new filter pad into the fan cover. It is inserted loosely in the fan cover. When
you insert the filter pad, make sure it lies evenly in the fan cover.
3. Replace the fan cover.
Note
Use of the filter pad
We advise against using filter pads that have already been used. If you do want to refit a
filter pad you have removed, however, take account of the direction in which the fan draws
air into the device. Make absolutely certain that you do not fit the outer side of the filter pad
on the inside. Generally, the outer side is clearly dirty after it has been in use for some time.
See also
Maintenance intervals (Page 82)
7.3.3

Replacing device fans

Requirement
● The device is fully disconnected from the line voltage, see section "Switching off the
device (Page 39)".
● The device is open; see section "Open the device. (Page 53)".
● 1 fan, article number 6BK1700-6HA71-0AA0
SIMATIC IPC1047
Operating Instructions, 07/2019, A5E45118479-AB
Device maintenance and repair
7.3 Removing and installing hardware
83

Advertisement