Summary of Contents for Siemens SIMATIC IPC PX-39A
Page 1
SIMATIC IPC PX-39A Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC PX-39A Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC PX-39A. History The following editions of these operating instructions have already been published:...
Page 4
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customers' exposure to cyber threats.
Mounting the device with mounting clips ................36 3.2.3 Fastening a device using a VESA adapter ................39 Connecting the device ....................... 41 3.3.1 Country-specific information on supply voltage ..............41 3.3.2 Connecting the protective conductor ................. 42 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 6
Installing/removing expansion modules (M.2) ..............69 Memory modules ....................... 72 6.5.1 Installing and removing a memory module ................ 72 Drives ..........................74 6.6.1 M.2 NVMe SSD in the SIMATIC IPC Slider ................74 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 7
Dimension drawing of 22" device with capacitive multi-touch screen ........97 Dimension drawing of 24" device with capacitive multi-touch screen ........99 Dimension drawing of the expansion cards ..............100 Dimension drawing of expansion modules (M.2) .............. 101 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 8
Technical support ..........................115 Service and support ......................115 Troubleshooting ......................116 B.2.1 Problems with device functions ..................116 B.2.2 Problems when booting the device .................. 117 B.2.3 Problems when using expansion cards ................117 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 9
Markings and symbols ........................118 Overview ......................... 118 Safety ..........................118 Operator controls......................118 Certificates, approvals and markings ................119 Interfaces ........................120 List of abbreviations .......................... 121 Abbreviations ........................121 Index ..............................123 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Boot modes Windows® operating Information on: • Online at: system • Commissioning the operating Microsoft® Windows® 10 system (https://support.industry.siemens. • Restoring the operating system com/cs/ww/en/view/109749498) • Configuration of the operating system SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 11
Information on: • Online at: bootable USB flash SIMATIC IPC Creating a bootable • Creating a bootable USB flash drive USB flash drive drive for recovery of operating (https://support.industry.siemens. system, software and drivers com/cs/ww/en/view/109811224) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Product description 1.2 Product highlights Product highlights The SIMATIC IPC PX-39A is a powerful Industrial Panel PC. It is perfectly suited for PC applications with high-level industry functionality. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
• Process and visualization applications • Industrial image processing • Quality assurance and monitoring tasks • Measurement, control and rule-based tasks • Data acquisition and management SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Interfaces of external expansion modules (M.2 format) interface X100 Device with expansion slot Other device variants (Page 49): • with slot for one PCIe expansion card You can find more information about expansion cards under "Expansion cards (Page 65)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Interfaces of external expansion modules (M.2 format) terface X100 Device with expansion slot Other device variants (Page 49): • with slot for one PCIe expansion card You can find more information about expansion cards under "Expansion cards (Page 65)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Status indicator Ethernet interfaces X3 P1 and X4 P1 Status display Status Meaning of the status LED 1 10 Mbps or 100 Mbps Lit orange 1000 Mbps LED 2 No connection Lit orange Connection exists Flashes orange Activity SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
24 V DC power supply ② Slot for memory module ③ Motherboard ④ Backup battery ⑤ Slots for M.2 expansion modules (under removable drives) ⑥ Slot for removable drives (SSD) ⑦ Heat conduction pad SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Accessories and spare parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. • When you install the device, make sure that the power supply connector is easily accessible. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 20
The device is tested and certified on the basis of the technical standards. In rare cases, functional restrictions can occur during plant operation. Validate the correct functioning of the plant to avoid functional restrictions. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 21
The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
DIN/VDE requirements or the applicable country-specific regulations. • Always maintain a minimum clearance of 50 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 24
• Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. See also Ambient conditions (Page 87) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• The IPC in question must be turned off and the power supply connector must be plugged • During the measurement, all cables from the plant to the IPC should be connected. • All other components in the plant must be active. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Functions may not work properly. This can result in personal injury or property damage. • Always connect the device to a protective conductor. • Additional information on connecting the protective conductor can be found in the section "Connecting the protective conductor (Page 42)." SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 27
Do not touch the screen in the following situations: • During the boot process • When plugging or unplugging USB components • While Scandisk is running • During a BIOS update SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
You will find the latest information on additional software for your device under: Accessories and spare parts (Page 18) Printed documents • Quick Install Guide SIMATIC IPC PX-39A • Product Information "Important notes on your device" SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the After Sales Information System (ASIS) (http://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The following figure shows the nameplate on the SIMATIC IPC PX-39A as an example. COA label The COA label (Certificate of Authenticity) is located on the side of the device.
For information on the maximum permissible ambient temperatures during operation, refer to section "AUTOHOTSPOT". Mounting in horizontal format Vertical mounting in horizontal format or inclined mounting in horizontal format with vertical inclination of max. ±45°: For temperature specifications, see section "AUTOHOTSPOT". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Permissible deviation from plane at the mounting cutout: ≤ 0.5 mm This condition must be fulfilled for the mounted HMI device. • Permissible surface roughness in the area of the mounting seal: ≤ 120 µm (R 120) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 34
22" 24" Width w Height h Width and height must be interchanged for mounting in vertical format. Installation depth Information on the overall depth is available in the section "Dimension drawings (Page 93)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Ensure there is enough clearance in the control cabinet to allow the backplane cover to be removed. • Equip the control cabinet with struts for stabilizing the mounting cut-out. Install struts where necessary. See also Mounting positions (Page 32) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Note If the mounting seal is damaged or protrudes from the device, the guaranteed degree of protection is not ensured. It is prohibited from mounting the device if the mounting seal is damaged. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 37
3. Insert a mounting clip into the cutout provided on the device. Note the correct position of the mounting clips. 4. To secure the mounting clip, tighten the grub screw with the slot screwdriver, torque 0.5 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 38
5. Repeat steps 3 and 4 until all mounting clips are securely fastened. 6. Check the fit of the mounting seal. Position of the mounting clips for multi-touch devices Fasten the mounting clips to the positions as illustrated. Device Position 24" display 22" display SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
3.2.3 Fastening a device using a VESA adapter You can also fasten the SIMATIC IPC PX-39A up to a display size of 24" using a 100 x 100 mm VESA adapter. Different models of VESA adapters are offered by third-party manufacturers.
Page 40
Procedure 1. Attach the VESA adapter 100 x 100 mm to the marked locations. 2. To do this, use M4x10 screws with property class 8.8 and tighten these with a torque of 3 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
2. Screw the cable lug onto the protective conductor connection as shown. 3. Wire the protective conductor to the protective conductor connection of the control cabi- net in which the device is installed. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Operation in non-grounded or impedance-grounded networks is not permitted. Note The varying voltage power supply module is designed for operation on 120/230/240 V AC networks. The setting of the voltage range takes place automatically. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 44
2. Insert the capacitor IEC plug at the marked position. 3. Connect the power cable with the safety power outlet. 4. If necessary, install the enclosed cable grip. See also Connecting the protective conductor (Page 42) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Make sure that the cores are connected to the correct terminals. Observe the labeling for the contacts on the device. 1. Connect the cables as shown with a tightening torque of 2.5 Nm. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
The 24 V DC power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 47
"O" (Off) to avoid uninten- tional startup of the device when you plug in the power cord. 2. Insert the terminal at the marked po- sition. 3. Secure the terminal using the inte- grated screws. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
The following table shows the various connection options for the monitors on the device interfaces. Motherboard DPP1 DPP2 Monitor 1 Monitor 2 1) - via DP to DVI-D adapter 2) - via DP-VGA adapter SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
9.3.2 of the IEC/UL/EN/DIN-EN 61010-2-201 standard. Requirements • The device is switched off. Procedure The procedure is described based on the example of a USB expansion card. 1. Connect the cable to one of the indicated slots. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Control level. You can find information on this under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrial- communications/Pages/Default.aspx). The software package and the documentation are not included in the scope of delivery. Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Cable ties (not included in the scope of delivery) Procedure 1. Pass the cable tie around the strain relief bar and secure the cables as shown. 2. Cut off the protruding ends of the cable ties. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Switching off the device Shutting down the operating system For active operating system • Shut down the operating system properly. Result The device is switched off but not fully disconnected from the line voltage. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 53
• Press the on/off switch to trigger a hardware reset, see "Interfaces and operator controls for devices with 24 V DC power supply (Page 14)" or "Interfaces and operator controls for devices with 100-240 V AC power supply (Page 15)". See also General safety instructions (Page 19) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Surface contact with a diameter of about 5 to 20 mm is required for an operator action to be detected. • An operation with gloves with a material thickness of < 2 mm is detected in most cases. Check the usefulness of the gloves you are using. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
– Ethernet Monitor settings For information on the software and documentation of "SIMATIC IPC Panel Drivers and Tools", refer to the detailed PDT description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
2. Configure the function "multi-monitoring" in the firmware/BIOS settings of the device. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
You can find information on the monitoring software and its documentation under: • SIMATIC IPC DiagBase (Page 58) for monitoring and alarming locally on the device • SIMATIC IPC DiagMonitor (Page 58) for monitoring and alarming via network SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
IPC DiagBase monitoring software is installed. Information on the software and documentation of SIMATIC IPC DiagBase can be found under: • SIMATIC IPC DiagBase (https://support.industry.siemens.com/cs/ww/en/view/109749690) • Important instructions and manuals for operating the device (Page 10) 5.3.3 SIMATIC IPC DiagMonitor The SIMATIC IPC DiagMonitor monitoring software can be ordered optionally.
You configure iAMT with Intel® Management Engine BIOS Extension (MEBx) in the firmware/BIOS. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
512 KB can be displayed by means of a PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the SIMATIC Software Controller. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 52)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 62
Expanding and assigning parameters to the device 6.1 Opening the Device Procedure 1. Remove the marked screws. 2. Lift off the front panel. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 52)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 64
6.2 Open device with expansion slot Procedure 1. Remove the marked screws. 2. Lift off the front panel in the direction of the arrow. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• You can find information on the type of expansion card you can install in specific slots under "Slot for expansion cards on the bus board (Page 109)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 66
2. Remove the retainer (2). 3. Insert the expansion card into the slot on the bus board (3). Secure the expansion card with the corre- sponding screw. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 67
Proceed in reverse order of installation. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion card. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• The connecting cable between M.2 modules and conditioner card should be at least 150 mm long. See also Position of the interfaces on the motherboard (Page 107) Dimension drawing of expansion modules (M.2) (Page 101) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Torx T10 and pull out the SSD drive bay upwards. Put down the SSD drive bay carefully on the side. Remove the designated screw on the motherboard with the screwdriver of the type Torx T8. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 70
Torx T10 screw- driver. Place the additional interface card from the inside against the empty enclosure opening and fasten it using the screw. Connect the cable of the interface card to the M.2 module. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 71
Proceed in reverse order of installation. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion module. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• Memory transaction rate 3200 MT/sec "unbuffered" • "without ECC" or "with ECC" Note Use only the memory modules recommended by Siemens AG. Requirement • The device is open, see important information under "Opening the device (Page 61)". Procedure - Removal 1.
Page 73
After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Procedure - Option 2 Loosen the screw of the removable slider with the Torx T10 type screwdriver. Remove the cover from the device and place it on the side. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 75
Place the slider on a suitable surface. Remove the marked screws with the screwdriver of type Torx T8. Remove the black plastic cover. Remove the marked screw with the screwdriver of type Torx T8. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 76
13. Place the slider cover in the device and fasten it with the Torx T10 type screw- driver. Note To ensure reliable operation of the devices with SIMATIC IPC Slider, the slider must be closed with the cover. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
As soon as the Smart status of the data storage medium goes to "Not OK", a message is generated in SIMATIC IPC DiagBase or SIMATIC IPC DiagMonitor or also during a system start of the device. You should then back up your data and replace the drive. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• See the notes under "Notes on ambient and environmental conditions (Page 23)". Cleaning the Device Front 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Clean the device with the cleaning cloth. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
(Page 10). • The device is open, see important information regarding this under Opening the Device (Page 61). • You have observed the local regulations relating to the disposal of used batteries. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Installing operating system, software and drivers You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
< 40 dB(A) according to DIN 45635-1 Degree of protection IP 20 according to IEC 60529 IP 65 (front) UL50E Type 1, 4X (indoor) and 12 Quality assurance In accordance with ISO 9001 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 83
The device may only be connected to a 24 V DC power supply that meets the require- ments for safe extra-low voltage (SELV/PELV) in accordance with the IEC/UL/EN/DIN-EN 61010-2-201 standard (see section "Connecting the 24 V DC power supply (Page 46)"). not evaluated by UL SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
0.5 A 12 W NVMe SSDs in the SIMATIC IPC Slider - addi- 0.25 A 5.9 W tional M.2 slots - additional 0.25 A 5.9 W PCIe slot - additional 0.38 A 9.2 W SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Max. 9 A for further 5 ms Max. 8 A for further 40 ms Max. 4.1 A²s • I²t value: Active power 94 W Output data Voltages +12 V / 6.7 A Secondary power output Max. 80 W SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Temperature 30 °C, relative humidity 85%; Permitted range: 0 to 31 °C: 5 ... 80%; decreasing linearly to 5 ... 25% at 55 °C - Storage/transport Temperature 25 °C - 55 °C, relative humidity 95% SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 88
This information applies to the setting "Balanced" in the BIOS Setup, Menu "Power" > "Power&Performance" > "CPU Power Management Control" > "CPU Power Level"; the am- bient temperature must be reduced by 5 °C for the setting "Max Performance". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-con- trolled via screen saver or centrally via PROFIenergy. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
No teaming with iAMT When using iAMT, the X1 P1 interface must be used to connect to remote maintenance. Only possible with ports X1 P1 and X2 P1 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
The following table lists the partitioning for disks ≥ 200 GB in GPT mode: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS Fourth WinRE 500 MB NTFS Fifth Data Remainder NTFS SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
• 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Panel PC certificates (http://support.automation.siemens.com/WW/view/en/10805572/134200). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
This product meets the requirements of EN 61000-6-3 Generic standards – Emission standard for industrial environments. This product meets the requirements of the standard EN 61000-6-3 Generic standards - Emission standard for industrial environments. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. 10.11 Taiwan Taiwan This product meets the requirements of the CNS14336-1(099/09/30), generic standard CNS13438(095/06/01). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Slots for expansion modules (M.2) ③ Backup battery ④ Slot for the bus board Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 89)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Internal M.2 Key B, assigned PCIe bus signals Port for SSD drive bay Internal Socket for SSD drive bay, assigned PCIe bus signals A.2.2 USB ports Designation VBUS_USB1 VBUS_USB2 USB1_D- USB2_D- USB1_D+ USB2_D+ SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
5 V voltage Output Ground + 3.3 V 3.3 V voltage Output max. permitted current: 1 A; with this current requirement, the total current requirement of the PCIe slot must not be exceeded. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
WDT counter register Base address + offset 7 WDT status register The following tables describe the system resources for the factory state of the device. See also Watchdog timer (WDT) register (read/write) (Page 113) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Reserved Reserved Reserved CMOS battery capacity is still sufficient CMOS battery capacity is exhausted (remain- ing capacity is still sufficient for approx. 1 month) CMOS battery is empty or missing Reserved Reserved Reserved SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
This step resets the "PC ON/WD" LED from pulsing red to its normal state (lit green). The WDT starts counting down. To prevent this behavior, stop the WDT before resetting the status to "Active". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After-sales information system for SIMATIC PC / PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
USB ports are disabled in the firm- Use a different USB port or activate the port. ware/BIOS Operating system does not support For other devices, you need the USB device drivers the USB port. for the required operating system. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
3. Set the respective setup parameter "PEG# - Gen X" perma- nently to "Gen1" in the "Advanced > Video Configuration" menu, submenu "Pci Expess Graphic" of the BIOS Setup. 4. Install the expansion card again. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- On/off switch, without electrical isola- tion tion SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
EFUP (Environment Friendly Use Pe- Approved for Korea riod) marking for China Test mark of the Underwriters Labora- UKCA marking for Great Britain tories Approval for India Disposal information, observe the lo- cal regulations. Approval for Taiwan SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Digital display interface with digital and VGA sig- nals Error checking and correction Error correction code Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
Page 122
US organization for tests and certifications accord- ing to own or binational standards (with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...