Siemens SIMATIC IPC PX-39A Operating Instructions Manual
Siemens SIMATIC IPC PX-39A Operating Instructions Manual

Siemens SIMATIC IPC PX-39A Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC PX-39A:
Table of Contents

Advertisement

Quick Links

SIMATIC IPC PX-39A
SIMATIC
Industrial PC
SIMATIC IPC PX-39A
Operating Instructions
08/2022
A5E51699601-AA
Preface
Product description
Safety instructions
Installing and connecting
the device
Commissioning the device
Operating the device
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Dimension drawings
Standards and approvals
Hardware description
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
9
10
A
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC PX-39A

  • Page 1 SIMATIC IPC PX-39A Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC PX-39A Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    General knowledge in the field automation control engineering is recommended. Scope of the operating instructions These operating instructions are valid for all order versions of the SIMATIC IPC PX-39A. History The following editions of these operating instructions have already been published:...
  • Page 4 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply latest updates may increase customers' exposure to cyber threats.
  • Page 5: Table Of Contents

    Mounting the device with mounting clips ................36 3.2.3 Fastening a device using a VESA adapter ................39 Connecting the device ....................... 41 3.3.1 Country-specific information on supply voltage ..............41 3.3.2 Connecting the protective conductor ................. 42 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 6 Installing/removing expansion modules (M.2) ..............69 Memory modules ....................... 72 6.5.1 Installing and removing a memory module ................ 72 Drives ..........................74 6.6.1 M.2 NVMe SSD in the SIMATIC IPC Slider ................74 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 7 Dimension drawing of 22" device with capacitive multi-touch screen ........97 Dimension drawing of 24" device with capacitive multi-touch screen ........99 Dimension drawing of the expansion cards ..............100 Dimension drawing of expansion modules (M.2) .............. 101 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 8 Technical support ..........................115 Service and support ......................115 Troubleshooting ......................116 B.2.1 Problems with device functions ..................116 B.2.2 Problems when booting the device .................. 117 B.2.3 Problems when using expansion cards ................117 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 9 Markings and symbols ........................118 Overview ......................... 118 Safety ..........................118 Operator controls......................118 Certificates, approvals and markings ................119 Interfaces ........................120 List of abbreviations .......................... 121 Abbreviations ........................121 Index ..............................123 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 10: Product Description

    • Boot modes Windows® operating Information on: • Online at: system • Commissioning the operating Microsoft® Windows® 10 system (https://support.industry.siemens. • Restoring the operating system com/cs/ww/en/view/109749498) • Configuration of the operating system SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 11 Information on: • Online at: bootable USB flash SIMATIC IPC Creating a bootable • Creating a bootable USB flash drive USB flash drive drive for recovery of operating (https://support.industry.siemens. system, software and drivers com/cs/ww/en/view/109811224) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 12: Product Highlights

    Product description 1.2 Product highlights Product highlights The SIMATIC IPC PX-39A is a powerful Industrial Panel PC. It is perfectly suited for PC applications with high-level industry functionality. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
  • Page 13: Applications

    • Process and visualization applications • Industrial image processing • Quality assurance and monitoring tasks • Measurement, control and rule-based tasks • Data acquisition and management SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 14: External Design Of The Device

    Interfaces of external expansion modules (M.2 format) interface X100 Device with expansion slot Other device variants (Page 49): • with slot for one PCIe expansion card You can find more information about expansion cards under "Expansion cards (Page 65)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 15: Interfaces And Operator Controls For Devices With 100-240 V Ac Power Supply

    Interfaces of external expansion modules (M.2 format) terface X100 Device with expansion slot Other device variants (Page 49): • with slot for one PCIe expansion card You can find more information about expansion cards under "Expansion cards (Page 65)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 16: Status Displays

    Status indicator Ethernet interfaces X3 P1 and X4 P1 Status display Status Meaning of the status LED 1 10 Mbps or 100 Mbps Lit orange 1000 Mbps LED 2 No connection Lit orange Connection exists Flashes orange Activity SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 17: Internal Design Of The Device

    24 V DC power supply ② Slot for memory module ③ Motherboard ④ Backup battery ⑤ Slots for M.2 expansion modules (under removable drives) ⑥ Slot for removable drives (SSD) ⑦ Heat conduction pad SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 18: Accessories And Spare Parts

    Accessories and spare parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall 1. On the Internet, go to Industry Mall (https://mall.industry.siemens.com).
  • Page 19: Safety Instructions

    • For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. • When you install the device, make sure that the power supply connector is easily accessible. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 20 The device is tested and certified on the basis of the technical standards. In rare cases, functional restrictions can occur during plant operation. Validate the correct functioning of the plant to avoid functional restrictions. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 21 The device contains electronic components which may be destroyed by electrostatic charge. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 22: Note On Transport And Storage

    • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 23: Notes On Mounting

    DIN/VDE requirements or the applicable country-specific regulations. • Always maintain a minimum clearance of 50 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 24 • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. • Read the information in the technical specifications. See also Ambient conditions (Page 87) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 25: Information On I/O Devices

    • The IPC in question must be turned off and the power supply connector must be plugged • During the measurement, all cables from the plant to the IPC should be connected. • All other components in the plant must be active. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 26: Notes On The Touch Screen

    Functions may not work properly. This can result in personal injury or property damage. • Always connect the device to a protective conductor. • Additional information on connecting the protective conductor can be found in the section "Connecting the protective conductor (Page 42)." SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 27 Do not touch the screen in the following situations: • During the boot process • When plugging or unplugging USB components • While Scandisk is running • During a BIOS update SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 28: Notes On Device And System Extensions

    • UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". • We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 29: Installing And Connecting The Device

    You will find the latest information on additional software for your device under: Accessories and spare parts (Page 18) Printed documents • Quick Install Guide SIMATIC IPC PX-39A • Product Information "Important notes on your device" SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 30: Checking The Delivery Package

    If the contents of the package are incomplete, damaged or do not correspond to your order, you can use the After Sales Information System (ASIS) (http://siemens.com/asis) to provide feedback on product deliveries and repairs. Complete the online form for product delivery (quality control notification) under the heading "Product delivery: Feedback on quality control and repairs".
  • Page 31: Identification Data Of The Device

    The following illustrations are examples. The data of your device may differ from the data in these examples. Nameplate The following figure shows the nameplate on the SIMATIC IPC PX-39A as an example. COA label The COA label (Certificate of Authenticity) is located on the side of the device.
  • Page 32: Mounting Positions

    For information on the maximum permissible ambient temperatures during operation, refer to section "AUTOHOTSPOT". Mounting in horizontal format Vertical mounting in horizontal format or inclined mounting in horizontal format with vertical inclination of max. ±45°: For temperature specifications, see section "AUTOHOTSPOT". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 33: Preparing The Mounting Cutout

    • Permissible deviation from plane at the mounting cutout: ≤ 0.5 mm This condition must be fulfilled for the mounted HMI device. • Permissible surface roughness in the area of the mounting seal: ≤ 120 µm (R 120) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 34 22" 24" Width w Height h Width and height must be interchanged for mounting in vertical format. Installation depth Information on the overall depth is available in the section "Dimension drawings (Page 93)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 35: Installing The Device

    • Ensure there is enough clearance in the control cabinet to allow the backplane cover to be removed. • Equip the control cabinet with struts for stabilizing the mounting cut-out. Install struts where necessary. See also Mounting positions (Page 32) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 36: Mounting The Device With Mounting Clips

    Note If the mounting seal is damaged or protrudes from the device, the guaranteed degree of protection is not ensured. It is prohibited from mounting the device if the mounting seal is damaged. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 37 3. Insert a mounting clip into the cutout provided on the device. Note the correct position of the mounting clips. 4. To secure the mounting clip, tighten the grub screw with the slot screwdriver, torque 0.5 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 38 5. Repeat steps 3 and 4 until all mounting clips are securely fastened. 6. Check the fit of the mounting seal. Position of the mounting clips for multi-touch devices Fasten the mounting clips to the positions as illustrated. Device Position 24" display 22" display SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 39: Fastening A Device Using A Vesa Adapter

    3.2.3 Fastening a device using a VESA adapter You can also fasten the SIMATIC IPC PX-39A up to a display size of 24" using a 100 x 100 mm VESA adapter. Different models of VESA adapters are offered by third-party manufacturers.
  • Page 40 Procedure 1. Attach the VESA adapter 100 x 100 mm to the marked locations. 2. To do this, use M4x10 screws with property class 8.8 and tighten these with a torque of 3 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 41: Connecting The Device

    The power supply cord and the plug connector must bear the prescribed markings. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 42: Connecting The Protective Conductor

    2. Screw the cable lug onto the protective conductor connection as shown. 3. Wire the protective conductor to the protective conductor connection of the control cabi- net in which the device is installed. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 43: Connecting The Power Supply

    • Operation in non-grounded or impedance-grounded networks is not permitted. Note The varying voltage power supply module is designed for operation on 120/230/240 V AC networks. The setting of the voltage range takes place automatically. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 44 2. Insert the capacitor IEC plug at the marked position. 3. Connect the power cable with the safety power outlet. 4. If necessary, install the enclosed cable grip. See also Connecting the protective conductor (Page 42) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 45: Connect Terminal For 24 V Dc

    Make sure that the cores are connected to the correct terminals. Observe the labeling for the contacts on the device. 1. Connect the cables as shown with a tightening torque of 2.5 Nm. Make sure the connection terminal is in the correct position as shown. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 46: Connecting The 24 V Dc Power Supply

    The 24 V DC power supply is protected against polarity reversal. If you mix up the 24 V DC connecting cables and ground, the device is not damaged but does not switch on. After the power supply has been connected correctly, the device will again be ready to operate. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 47 "O" (Off) to avoid uninten- tional startup of the device when you plug in the power cord. 2. Insert the terminal at the marked po- sition. 3. Secure the terminal using the inte- grated screws. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 48: Connecting I/O Devices

    The following table shows the various connection options for the monitors on the device interfaces. Motherboard DPP1 DPP2 Monitor 1 Monitor 2 1) - via DP to DVI-D adapter 2) - via DP-VGA adapter SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 49: Connecting Expansion Cards

    9.3.2 of the IEC/UL/EN/DIN-EN 61010-2-201 standard. Requirements • The device is switched off. Procedure The procedure is described based on the example of a USB expansion card. 1. Connect the cable to one of the indicated slots. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 50: Connecting The Device To Networks

    Control level. You can find information on this under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrial- communications/Pages/Default.aspx). The software package and the documentation are not included in the scope of delivery. Additional information You can find additional information on the Internet at: Technical Support (https://support.industry.siemens.com). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 51: Securing The Lines

    • Cable ties (not included in the scope of delivery) Procedure 1. Pass the cable tie around the strain relief bar and secure the cables as shown. 2. Cut off the protruding ends of the cable ties. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 52: Commissioning The Device

    Switching off the device Shutting down the operating system For active operating system • Shut down the operating system properly. Result The device is switched off but not fully disconnected from the line voltage. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 53 • Press the on/off switch to trigger a hardware reset, see "Interfaces and operator controls for devices with 24 V DC power supply (Page 14)" or "Interfaces and operator controls for devices with 100-240 V AC power supply (Page 15)". See also General safety instructions (Page 19) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 54: Operating The Device

    • Surface contact with a diameter of about 5 to 20 mm is required for an operator action to be detected. • An operation with gloves with a material thickness of < 2 mm is detected in most cases. Check the usefulness of the gloves you are using. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 55: Simatic Ipc Panel Drivers And Tools

    – Ethernet Monitor settings For information on the software and documentation of "SIMATIC IPC Panel Drivers and Tools", refer to the detailed PDT description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 56: Multi-Monitoring

    2. Configure the function "multi-monitoring" in the firmware/BIOS settings of the device. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 57: Monitoring Of The Device

    You can find information on the monitoring software and its documentation under: • SIMATIC IPC DiagBase (Page 58) for monitoring and alarming locally on the device • SIMATIC IPC DiagMonitor (Page 58) for monitoring and alarming via network SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 58: Simatic Ipc Diagbase

    IPC DiagBase monitoring software is installed. Information on the software and documentation of SIMATIC IPC DiagBase can be found under: • SIMATIC IPC DiagBase (https://support.industry.siemens.com/cs/ww/en/view/109749690) • Important instructions and manuals for operating the device (Page 10) 5.3.3 SIMATIC IPC DiagMonitor The SIMATIC IPC DiagMonitor monitoring software can be ordered optionally.
  • Page 59: Remote Maintenance Of The Device

    You configure iAMT with Intel® Management Engine BIOS Extension (MEBx) in the firmware/BIOS. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 10)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 60: Trusted Platform Module (Tpm)

    512 KB can be displayed by means of a PCI address register. The base address is initialized by the BIOS. A corresponding function is implemented there for using the SIMATIC Software Controller. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 61: Expanding And Assigning Parameters To The Device

    Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 52)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 62 Expanding and assigning parameters to the device 6.1 Opening the Device Procedure 1. Remove the marked screws. 2. Lift off the front panel. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 63: Open Device With Expansion Slot

    Take corresponding precautionary measures before you open the device. Requirements • The device is fully disconnected from the line voltage, see "Switching off the device (Page 52)". • All connecting cables are unplugged. • Screwdriver of type Torx T10 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 64 6.2 Open device with expansion slot Procedure 1. Remove the marked screws. 2. Lift off the front panel in the direction of the arrow. 3. Put down the front panel. Close the device in reverse order. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 65: Expansion Cards

    • You can find information on the type of expansion card you can install in specific slots under "Slot for expansion cards on the bus board (Page 109)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 66 2. Remove the retainer (2). 3. Insert the expansion card into the slot on the bus board (3). Secure the expansion card with the corre- sponding screw. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 67 Proceed in reverse order of installation. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion card. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 68: Expansion Modules (M.2)

    • The connecting cable between M.2 modules and conditioner card should be at least 150 mm long. See also Position of the interfaces on the motherboard (Page 107) Dimension drawing of expansion modules (M.2) (Page 101) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 69: Installing/Removing Expansion Modules (M.2)

    Torx T10 and pull out the SSD drive bay upwards. Put down the SSD drive bay carefully on the side. Remove the designated screw on the motherboard with the screwdriver of the type Torx T8. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 70 Torx T10 screw- driver. Place the additional interface card from the inside against the empty enclosure opening and fasten it using the screw. Connect the cable of the interface card to the M.2 module. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 71 Proceed in reverse order of installation. Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion module. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 72: Memory Modules

    • Memory transaction rate 3200 MT/sec "unbuffered" • "without ECC" or "with ECC" Note Use only the memory modules recommended by Siemens AG. Requirement • The device is open, see important information under "Opening the device (Page 61)". Procedure - Removal 1.
  • Page 73 After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 74: Drives

    Procedure - Option 2 Loosen the screw of the removable slider with the Torx T10 type screwdriver. Remove the cover from the device and place it on the side. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 75 Place the slider on a suitable surface. Remove the marked screws with the screwdriver of type Torx T8. Remove the black plastic cover. Remove the marked screw with the screwdriver of type Torx T8. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 76 13. Place the slider cover in the device and fasten it with the Torx T10 type screw- driver. Note To ensure reliable operation of the devices with SIMATIC IPC Slider, the slider must be closed with the cover. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 77: Device Maintenance And Repair

    As soon as the Smart status of the data storage medium goes to "Not OK", a message is generated in SIMATIC IPC DiagBase or SIMATIC IPC DiagMonitor or also during a system start of the device. You should then back up your data and replace the drive. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 78: Cleaning The Device Front

    • See the notes under "Notes on ambient and environmental conditions (Page 23)". Cleaning the Device Front 1. Switch off the device. 2. Dampen the cleaning cloth. 3. Clean the device with the cleaning cloth. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 79: Removing And Installing Hardware

    (Page 10). • The device is open, see important information regarding this under Opening the Device (Page 61). • You have observed the local regulations relating to the disposal of used batteries. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 80: Installing Operating System, Software And Drivers

    Installing operating system, software and drivers You can restore the factory settings of the target system (i.e. the volume partitions, the operating system with installed device drivers, and the SIEMENS software products). This allows you to restore your device quickly if it has suffered damage.
  • Page 81: Configuring Firmware/Bios

    Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 82: Technical Specifications

    < 40 dB(A) according to DIN 45635-1 Degree of protection IP 20 according to IEC 60529 IP 65 (front) UL50E Type 1, 4X (indoor) and 12 Quality assurance In accordance with ISO 9001 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 83 The device may only be connected to a 24 V DC power supply that meets the require- ments for safe extra-low voltage (SELV/PELV) in accordance with the IEC/UL/EN/DIN-EN 61010-2-201 standard (see section "Connecting the 24 V DC power supply (Page 46)"). not evaluated by UL SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 84: Current/Power Requirements And Power Supply

    0.5 A 12 W NVMe SSDs in the SIMATIC IPC Slider - addi- 0.25 A 5.9 W tional M.2 slots - additional 0.25 A 5.9 W PCIe slot - additional 0.38 A 9.2 W SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 85: Technical Specifications Ac Power Supply (Ac)

    Max. 9 A for further 5 ms Max. 8 A for further 40 ms Max. 4.1 A²s • I²t value: Active power 94 W Output data Voltages +12 V / 6.7 A Secondary power output Max. 80 W SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 86: Electromagnetic Compatibility

    3 V/m 2.7 – 6 GHz, 80% AM to IEC 61000-4-3 • 10 V 10 KHz – 80 MHz, 80% AM to IEC 61000-4-6 Immunity to magnetic fields 100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 87: Ambient Conditions

    Temperature 30 °C, relative humidity 85%; Permitted range: 0 to 31 °C: 5 ... 80%; decreasing linearly to 5 ... 25% at 55 °C - Storage/transport Temperature 25 °C - 55 °C, relative humidity 95% SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 88 This information applies to the setting "Balanced" in the BIOS Setup, Menu "Power" > "Power&Performance" > "CPU Power Management Control" > "CPU Power Level"; the am- bient temperature must be reduced by 5 °C for the setting "Max Performance". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 89: Technical Specifications Of The Drives

    Slot for expansion card Slot for expansion card IPC PX-39A with one expansion slot (Bus board 1 x PCIe) Slot 1 PCI Express x4 (mechanical x8): Specification Rev. 4.0, length: Max. 175 mm SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 90: Technical Specifications Of Graphics/Display

    MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-con- trolled via screen saver or centrally via PROFIenergy. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 91: Technical Specifications Of The Interfaces

    No teaming with iAMT When using iAMT, the X1 P1 interface must be used to connect to remote maintenance. Only possible with ports X1 P1 and X2 P1 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 92: Technical Specifications Of The Operating Systems

    The following table lists the partitioning for disks ≥ 200 GB in GPT mode: Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS Fourth WinRE 500 MB NTFS Fifth Data Remainder NTFS SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 93: Dimension Drawings

    Dimension drawings Dimension drawing of 15" device with capacitive multi-touch screen Device without expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 94 Dimension drawings 9.1 Dimension drawing of 15" device with capacitive multi-touch screen Device with expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 95: Dimension Drawing Of 19" Device With Capacitive Multi-Touch Screen

    Dimension drawings 9.2 Dimension drawing of 19" device with capacitive multi-touch screen Dimension drawing of 19" device with capacitive multi-touch screen Device without expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 96 Dimension drawings 9.2 Dimension drawing of 19" device with capacitive multi-touch screen Device with expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 97: Dimension Drawing Of 22" Device With Capacitive Multi-Touch Screen

    Dimension drawings 9.3 Dimension drawing of 22" device with capacitive multi-touch screen Dimension drawing of 22" device with capacitive multi-touch screen Device without expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 98 Dimension drawings 9.3 Dimension drawing of 22" device with capacitive multi-touch screen Device with expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 99: Dimension Drawing Of 24" Device With Capacitive Multi-Touch Screen

    Dimension drawings 9.4 Dimension drawing of 24" device with capacitive multi-touch screen Dimension drawing of 24" device with capacitive multi-touch screen Device without expansion card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 100: Dimension Drawing Of The Expansion Cards

    Dimension drawings 9.5 Dimension drawing of the expansion cards Device with expansion card Dimension drawing of the expansion cards SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 101: Dimension Drawing Of Expansion Modules (M.2)

    Dimension drawings 9.6 Dimension drawing of expansion modules (M.2) Dimension drawing of expansion modules (M.2) Maximum dimensions of expansion modules Dimension drawing of the conditioner card SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 102: Standards And Approvals

    • 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EU Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Panel PC certificates (http://support.automation.siemens.com/WW/view/en/10805572/134200). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 103: Ukca Marking

    DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 104: Fcc (Usa)

    This product meets the requirements of EN 61000-6-3 Generic standards – Emission standard for industrial environments. This product meets the requirements of the standard EN 61000-6-3 Generic standards - Emission standard for industrial environments. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 105: Eurasion Customs Union Eac

    이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. 10.11 Taiwan Taiwan This product meets the requirements of the CNS14336-1(099/09/30), generic standard CNS13438(095/06/01). SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 106: Hardware Description

    Slots for expansion modules (M.2) ③ Backup battery ④ Slot for the bus board Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 89)". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 107: Position Of The Interfaces On The Motherboard

    (11) USB 2.0 (X600 Internal 3) (X1 P1 iAMT-capable/X2 P1) (4) 2 × Ethernet (8) M.2 PCIe interface (X100) (12) USB 2.0 (X610 Internal (X3 P1/X4 P1) 4/X610 Internal 5) (13) Power supply (X10) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 108: Internal Interfaces

    Internal M.2 Key B, assigned PCIe bus signals Port for SSD drive bay Internal Socket for SSD drive bay, assigned PCIe bus signals A.2.2 USB ports Designation VBUS_USB1 VBUS_USB2 USB1_D- USB2_D- USB1_D+ USB2_D+ SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 109: Bus Board

    5 V voltage Output Ground + 3.3 V 3.3 V voltage Output max. permitted current: 1 A; with this current requirement, the total current requirement of the PCIe slot must not be exceeded. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 110: External Interfaces

    USB 3.2 X60, X61 USB 3.2 Gen 2 socket type A X62, X63 Ethernet 1, 2, 3 X1 P1, RJ45 and 4 X2 P1, X3 P1, X4 P1 X70, X71 20-pin DisplayPort connector SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 111: System Resources

    WDT counter register Base address + offset 7 WDT status register The following tables describe the system resources for the factory state of the device. See also Watchdog timer (WDT) register (read/write) (Page 113) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 112: Battery Status Register (Read Only)

    Reserved Reserved Reserved CMOS battery capacity is still sufficient CMOS battery capacity is exhausted (remain- ing capacity is still sufficient for approx. 1 month) CMOS battery is empty or missing Reserved Reserved Reserved SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 113: Watchdog Timer (Wdt) Register (Read/Write)

    This step resets the "PC ON/WD" LED from pulsing red to its normal state (lit green). The WDT starts counting down. To prevent this behavior, stop the WDT before resetting the status to "Active". SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 114: Nvram Address Register

    NVRAM address register PCI register address: PCI register content: Length of the memory area NVRAM base address register NVRAM memory address (default) E300 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 115: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (https://www.siemens.com/supportrequest) • After-sales information system for SIMATIC PC / PG (https://www.siemens.com/asis) • SIMATIC Documentation Collection (https://www.siemens.com/simatic-tech-doku-portal) • Your local representative (https://www.automation.siemens.com/aspa_app) • Training center (https://siemens.com/sitrain) •...
  • Page 116: Troubleshooting

    USB ports are disabled in the firm- Use a different USB port or activate the port. ware/BIOS Operating system does not support For other devices, you need the USB device drivers the USB port. for the required operating system. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 117: Problems When Booting The Device

    3. Set the respective setup parameter "PEG# - Gen X" perma- nently to "Gen1" in the "Advanced > Video Configuration" menu, submenu "Pci Expess Graphic" of the BIOS Setup. 4. Install the expansion card again. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 118: Markings And Symbols

    Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- On/off switch, without electrical isola- tion tion SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 119: Certificates, Approvals And Markings

    EFUP (Environment Friendly Use Pe- Approved for Korea riod) marking for China Test mark of the Underwriters Labora- UKCA marking for Great Britain tories Approval for India Disposal information, observe the lo- cal regulations. Approval for Taiwan SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 120: Interfaces

    LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus interface SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 121: List Of Abbreviations

    Digital display interface with digital and VGA sig- nals Error checking and correction Error correction code Extensible Firmware Interface Electrostatic-sensitive components European standard Ground Chassis ground Hard Disk Drive Hard disk drive Height unit SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 122 US organization for tests and certifications accord- ing to own or binational standards (with CSA / Canada) standards. Universal Serial Bus Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 123: Index

    Motherboard Dimensions, 82, 93, 95, 97, 99 Design, 106 Dimensions of the device, 93, 95, 97, 99 Mounting Drive Modules, 49, 66, 69 Replace in the SIMATIC IPC Slider, 74 Multi-touch device, 36 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...
  • Page 124 AC voltage supply, 85 Weight, 82 Connecting, 47 WinAC module WinAC module, 109 Power supply connection, 109 Processor, 89 PROFIBUS, 50 PROFINET, 50 Protective conductor, 26, 42 Connecting, 42 Protective conductor connection, 26 SIMATIC IPC PX-39A Operating Instructions, 08/2022, A5E51699601-AA...

Table of Contents