7.7.2
Editing BICO values
You can use the BICO editor to enter BICO values for drive parameters.
Note
BICO values can also be entered by copying and inserting or also directly entered the field.
Procedure
Note
The BICO editor also opens if you enter a value other than 0 or 1 for the value to be
changed.
7.7.3
Editing enum values
For drive parameters, you have the option of editing enum elements (e.g. r2, p3, p4, p97
etc.) using a selection list.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
1.
Select the "Start-up" operating area.
2.
Press the "Mach. data" softkey.
3.
Press the "Control unit MD" softkey and select a BICO parameter, e.g.
"p738".
4.
Position the cursor on the entry to be changed, e.g. BICO 63.2091.0
5.
Press the <SELECT> or <INSERT> key.
The "BICO Editor" window opens.
6.
Complete the "Drive object number", "Parameter number", "Bit/Index"
and "Parameter value (hex)" fields.
Machine and setting data
7.7 Editing machine data and drive parameters
79