Procedure:
1. Call your own run up screen "
2. Save your own run up screen in one of the following directories:
6.8
Switching EXTCALL off
It is possible to access files located on network drives from a part program using the
EXTCALL command.
EXTCALL must be switched off, when in certain configurations two SINUMERIK Operate are
connected to one NCU.
Setting
Processing EXTCALL calls is switched-on or switched-off using the following display
machine data.
MD9106 $MM_SERVE_EXTCALL_PROGRAMS
= 0
= 1
6.9
Access levels
6.9.1
Definition of access levels
Access to programs, data and functions is protected in a user-oriented hierarchical system of
seven access levels. These are divided into
● Three password levels for manufacturer, service and users
● Four keyswitch positions for users
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Note
The file name must not contain any lower case letters.
/user/sinumerik/hmi/ico/ico640 or
/oem/sinumerik/hmi/ico/ico640 or
/addon/sinumerik/hmi/ico/ico640
Note
The size of the screen is of no significance. A resolution of 640x480 pixels is always set.
Switch off call processing
Switch on call editing (default value)
".
splash.png
General settings
6.8 Switching EXTCALL off
57