Status display:
– [0] "Not initialized"
– [1] "Establish communication after booting"
– [2] "Establish communication after error"
– [3] "Wait for checkback signals SN=1"
– [4] "Receiver waits for user acknowledgement"
– [5] "Normal operation"
1.
The "SI communication (general)" window with the communication data
is opened.
2.
Press the "Receive connection" softkey.
The "SI communication (send)" window is opened.
3.
Press the "Connection +" or "Connection -" softkey to select the
connection whose data you wish to display.
4.
Press the "Display SPL connection " softkey to display additional
details, e.g. connection data that has been set.
The softkey is only available if send connections have been configured.
5.
Press the "Display connection" softkey to return to the window with the
receive connections of the selected connection.