SI communication send connections

The configuration as well as the status of F_SENDDP are displayed in the SI communication
(send)" window.
Displayed signals
The following signals of the selected connection are displayed:
● CPU-CPU communication ID
● Logical base address
● Connection number
● Maximum parameterized communication time
● Actual communication time
● Maximum communication time
● Error reaction
● Error
● Diagnostics error code
● Substitute values active
● Actual communication data
● Driver state
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Error reactions that can be set:
– [0] "Alarm 27350 + STOP D/E"
– [1] "Alarm 27350"
– [2] "Alarm 27351 (self clearing)"
– [3] "No reaction"
Status display:
– [0] "Not initialized"
– [1] "Establish communication after booting"
– [2] "Establish communication after error"
– [3] "Wait for checkback signals SN=1"
– [4] "Receiver waits for user acknowledgement"
– [5] "Normal operation"
Safety Integrated
21.2 Safety Integrated diagnostics
447