Siemens SINUMERIK 840D sl Commissioning Manual page 185

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Example 2
Also in this example, the prepared texts for the reason for the change are used. It is only
permitted to enter one reason for the change as a valid entry. The reason for the tool change
is saved in the local variable of the SlCap service.
<TOOLCHANGEREASON>
</TOOLCHANGEREASON>
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
<Enabled value="true" type="bool" />
<OnlyOneReasonAllowed value="true" type="bool" />
<UseCapLocalParameter value="true" type="bool" />
<REASON1>
<Text value="TM_DGL_DESIRED_PIECES_ELAPSED" type="QString" />
<BitMask value="1" type="int" />
</REASON1>
<REASON2>
<Text value="TM_DGL_TOOL_BREAKAGE" type="QString" />
<BitMask value="2" type="int" />
</REASON2>
<REASON3>
<Text value="TM_DGL_CUTTING_EDGE_DAMAGE" type="QString" />
<BitMask value="4" type="int" />
</REASON3>
<REASON4>
<Text value="TM_DGL_PREMATURE_WEAR" type="QString" />
<BitMask value="8" type="int" />
</REASON4>
<REASON5>
<Text value="TM_DGL_TYPE_REEQUIPPING" type="QString" />
<BitMask value="16" type="int" />
</REASON5>
<REASON6>
<Text value="TM_DGL_TOOL_TRIAL" type="QString" />
<BitMask value="32" type="int" />
</REASON6>
<REASON7>
<Text value="TM_DGL_PREVENTIVE_CHANGE" type="QString" />
<BitMask value="64" type="int" />
</REASON7>
Tool management
12.2 Configuring the user interface
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents