Siemens SINUMERIK 840D sl Commissioning Manual page 899

Basesoftware and operating software
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning the system
1.1
Delivery condition of the system
Overview
The PCU has onboard interfaces for communicating via Ethernet, MPI and PROFIBUS DP.
The integrated free slots remain free for other tasks. The PCU is equipped with the
Windows XP ProEmbSys operating system and for data backup tasks with the Symantec
Ghost software.
Interfaces:
● Four USB ports (USB 2.0) offer points where a keyboard, mouse and other peripheral
● For CF cards, there is a covered slot.
● Two internal PCI slots are available for specific expansions.
For commissioning:
● Two 7-segment displays and two LEDs are integrated for diagnostic purposes. They
● If the PCU is to be operated without an operator panel front, a monitor and an additional
References: Operator Components and Networking Manual
Supplied software on the PCU
The software installed on delivery of the PCU includes the components below, among
others:
MS Windows XP Professional SP3
Internet Explorer
MPI driver (PCU 50.3 and PCU 50.5-C)
Symantec Ghost (default setting)
TCU Support
(is already installed and available on the hard disk under
D:\Updates, if it must be re-installed.)
PCU-Basesoftware (IM8)
Commissioning Manual, 02/2012, 6FC5397-1DP40-3BA0
devices can be connected.
indicate the current operating status and display the BIOS error codes during boot up.
keyboard will also be required:
– For diagnostics when booting the PCU
– When installing a replacement hard disk
(alternatively, the hard disk can also be installed externally).
V 6.0
V 6.04.01.00
V 8.2 (incl. Ghost Explorer)
V 8.6