Creating drive connections

4.2 File "logdrive.ini"

Procedure
4.2
File "logdrive.ini"
Configurations of drives in the "Logical Drives" window are saved in the "logdrive.ini" file.
Structure of the "logdrive.ini" file
● You define all logical drives in section [CONNECTIONS].
● You can enter the number of the logical drives next to "ConnectionNum".
34
1.
Select the "Start-up" operating area.
2.
Press the "HMI" and "Log. drive" softkeys.
The "Set Up Drives" window opens.
3.
Select the data for the corresponding drive or enter the necessary data.
4.
Press the "Activate drive" softkey.
The drive is activated.
The operating system now checks the entered data and whether the
connection is established. An OK message is output in the dialog line if
an error is not identified.
The drive can be accessed.
- OR -
If the operating system identifies an error, then you receive an error
message.
Press the "OK" softkey.
You then return to the "Set Up Drives" window. Check and correct your
entries and re-activate the drive.
If you press the "OK" softkey, the modified data is accepted without any
feedback message. You do not receive any message about a successful
or unsuccessful connection.
If you press the "Cancel" softkey, then all of the data that has not been
activated is rejected.
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1