Tool management
12.2 Configuring the user interface
Entries
ReactivateWithMagPos
ReactivateAllMonitorModes
ReactivateEnabled
CreateNewToolDialog
CreateNewMultiToolDialog
MagazineSelectionDialog
NewToolFavoritesOnly
134
Meaning
True - reactivate with positioning of the tool to the tool
magazine loading point.
False - default setting, reactivate without positioning the
tool magazine.
True - the actual values of all the monitoring types set in
the NC are reset.
False - default setting, actual value of the active
monitoring type is reset.
True - default setting, reactivation is enabled.
False - reactivation is disabled.
True - the "New Tool" window is displayed. In this
window, you can specify the tool name and the size of
the tool (oversized tool) before actually creating the tool.
Other input options can be defined by configuring the
"New tool" window.
False - default setting, the "New Tool" window is not
displayed. Once the name has been entered, the tool will
be created directly in the tool list.
True - default setting, the "New Multitool" window is
displayed. In this window, you can configure the
following before actually creating the multitool:
Multitool names
Number of multitool locations
Type of clearance input
Value of the location clearance for each multitool
location
False - the "New Multitool" window is not displayed.
Once the name has been entered, the multitool will be
created directly in the tool list.
True - a dialog box displaying the buffer, tool magazine
and NC memory is displayed. A mark can be added to or
removed from each of these elements to indicate
whether that element appears in the list display. The "Go
to" softkey can be used to select an element directly in
the list display.
False - no dialog box for magazine selection. The
system switches between the buffer, the tool magazines
and the NC memory.
If there is no MagazineSelectionDialog entry in the
<
> tag, the dialog box is automatically
Settings
displayed with more than one tool magazine (excluding
the system magazine) when magazine configuration is
taking place. If there is only one tool magazine, the
switchover function is used.
Refers to the "New tool" function.
True - only those tool types that are configured as
favorites are listed.
False - default setting, all tool types are listed.