Basic Setting Parameters ([Pr. Pa - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

7. PARAMETERS

7.1.1 Basic setting parameters ([Pr. PA_ _ ])

No.
Symbol
PA01
*STY
Operation mode
PA02
*REG
Regenerative option
PA03
*ABS
Absolute position detection system
PA04
*AOP1
Function selection A-1
PA05
*FBP
Number of command input pulses per revolution
PA06
*CMX
Electronic gear numerator (command pulse multiplication
numerator)
Number of gear teeth on machine side
PA07
*CDV
Electronic gear denominator (command pulse multiplication
denominator)
Number of gear teeth on servo motor side
PA08
ATU
Auto tuning mode
PA09
RSP
Auto tuning response
PA10
INP
In-position range
PA11
TLP
Forward rotation torque limit/positive direction thrust limit
PA12
TLN
Reverse rotation torque limit/negative direction thrust limit
PA13
*PLSS
Command pulse input form
PA14
*POL
Rotation direction selection/travel direction selection
PA15
*ENR
Encoder output pulses
PA16
*ENR2
Encoder output pulses 2
PA17
*MSR
Servo motor series setting
PA18
*MTY
Servo motor type setting
PA19
*BLK
Parameter writing inhibit
PA20
*TDS
Tough drive setting
PA21
*AOP3
Function selection A-3
PA22
*PCS
Position control composition selection
PA23
DRAT
Drive recorder arbitrary alarm trigger setting
PA24
AOP4
Function selection A-4
PA25
OTHOV
One-touch tuning - Overshoot permissible level
PA26
*AOP5
Function selection A-5
PA27
For manufacturer setting
PA28
PA29
PA30
PA31
PA32
POINT
To enable the following parameters in a positioning mode, cycle the power after
setting.
[Pr. PA06 Electronic gear numerator (command pulse multiplication
numerator)/Number of gear teeth on machine side]
[Pr. PA06 Electronic gear denominator (command pulse multiplication
denominator)/Number of gear teeth on servo motor side]
The following parameter cannot be used in the positioning mode.
[Pr. PA05 Number of command input pulses per revolution]
Name
7 - 3
www.kavrammuhendislik.com.tr
Operation
mode
Initial
Unit
value
1000h
0000h
0000h
2000h
10000
1
1
1
1
0001h
16
[μm]/
100
-4
10
[inch]/
-3
10
[degree]/
[pulse]
100.0
[%]
100.0
[%]
0100h
0
4000
[pulse/rev]
1
0000h
0000h
00AAh
0000h
0001h
0000h
0000h
0000h
0
[%]
0000h
0000h
0000h
0000h
0000h
0000h
0000h
Control
mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents