Automatic Positioning To Home Position Function - Mitsubishi Electric MELSERVO-J4 Series Instruction Manual

General-purpose interface ac servo. servo amplifier
Hide thumbs Also See for MELSERVO-J4 Series:
Table of Contents

Advertisement

4. HOW TO USE THE POINT TABLE

4.4.14 Automatic positioning to home position function

After power-on, if the home position return is performed again after the home position return is performed to
define the home position, this function enables automatic positioning to the home position rapidly. For the
absolute position detection system, the home position return is unnecessary after the power-on.
When the automatic positioning to the home position is performed at home position return incompletion, [AL.
90.1] will occur.
After the power-on, perform the home position return in advance.
Set input devices and parameters as follows.
Item
Home position return mode
selection
Home position return speed
Home position return
acceleration/deceleration time
constant
Home position return
direction
Set the home position return speed of the automatic positioning to home position function with [Pr. PT05].
The data of point table No. 1 is used for acceleration/deceleration time constants. Switching on ST2
(Reverse rotation start) enables high-speed automatic return.
Set the rotation direction at the time of degree unit setting with home position return direction of [Pr. PT04].
POINT
The automatic positioning to the home position cannot be performed from
outside the setting range of position data. In this case, perform the home
position return again using the home position return.
Used device/parameter
MD0 (Operation mode selection 1)
DI0 (Point table No. selection 1) to
DI7 (Point table No. selection 8)
[Pr. PT05]
Point table No. 1
[Pr. PT04]
MD0 (Operation mode selection 1)
Forward rotation
Servo motor speed
0 r/min
Reverse rotation
ST1 (Forward rotation start)
ST2 (Reverse rotation start)
4 - 68
www.kavrammuhendislik.com.tr
Switch on MD0.
Switch off DI0 to DI7.
Set the servo motor speed to travel to the
home position.
Use the acceleration/deceleration time
constant of point table No. 1.
Set the rotation direction in degrees.
ON
Acceleration time
OFF
constant
Home position
return speed
3 ms or shorter
ON
OFF
ON
5 ms or longer
OFF
Setting
Deceleration time
constant
Home position

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents