5. HOW TO USE THE PROGRAM
2) Program example 2
Command
SPN (1000)
STC (20)
MOVI (1000)
TIM (200)
OUTON (1)
MOVI (500)
STOP
3) Program example 3
Command
SPN (1000)
STC (20)
MOVI (1000)
OUTON (1)
TIM (200)
MOVI (500)
STOP
Servo motor speed
Acceleration/deceleration time
constant
Incremental value travel command
Dwell
Switch on OUT1 (Program output 1).
Incremental value travel command
Program stop
Forward rotation
Servo motor speed
0 r/min
Reverse rotation
OUT1
(Program output 1)
Servo motor speed
Acceleration/deceleration time
constant
Incremental value travel command
Switch on OUT1 (Program output 1).
Dwell
Incremental value travel command
Program stop
Servo motor speed
OUT1
(Program output 1)
www.kavrammuhendislik.com.tr
Description
1000 [r/min]
20 [ms]
STM
μm]
1000 [×10
200 [ms]
STM
μm]
500 [×10
ON
OFF
Description
1000 [r/min]
20 [ms]
STM
μm]
1000 [×10
200 [ms]
STM
μm]
500 [×10
Forward rotation
0 r/min
Reverse rotation
ON
OFF
a)
5 - 19
a)
b)
a) 200 ms
b)
a)
b)
b) 200 ms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mr-j4-03a6-rj

Table of Contents