4. HOW TO USE THE POINT TABLE
c) Position data in degrees
The following shows an operation example with the set values listed in the table below.
In this example, point table No. 1, point table 2, and point table No. 4 are under the absolute
value command method, and point table No. 3 is under the incremental value command
method.
Point table
Position data
No.
[degree]
1
120.000
2
-320 .000
3
-230.000
4
70.000
Note. Always set "0" or "2" to the auxiliary function of the last point table among the consecutive point tables.
0: When using the point table under the absolute value command method
2: When using the point table under the incremental value command method
Servo motor speed
Point table No. to select
ST1 (Forward rotation start)
PT0 (Point table No. output 1)
to PT7 (Point table No. output 8)
(Note)
M code output
Note. For MR-J4-03A6-RJ servo amplifiers, up to six points of DO are available; therefore, PT0 to PT7 cannot be
outputted simultaneously.
Acceleration
Servo motor
time constant
speed [r/min]
[ms]
1000
100
500
150
3000
200
1500
300
Home position → Point table No. 1
0
120
(-240)
Point table No. 2 → No. 3
0
40
(-320)
230
170
(-190)
Point table No. 1
Forward rotation
0 r/min
Reverse rotation
Point table No. 2
ON
OFF
4 - 22
www.kavrammuhendislik.com.tr
Deceleration
time constant
Dwell [ms]
[ms]
150
100
100
200
300
150
100
Disabled
120
(-240)
70
(-290)
Point table No. 3
1
Auxiliary
M code
function
1
05
1
10
3
15
0 (Note)
20
Point table No. 1 → No. 2
0
40
(-320)
Point table No. 3 → No. 4
0
170
(-190)
Point table No. 4
1
05