How To Connect Fibre Channel Cables From File Modules To The Control Enclosure; Error Code Port Location Mapping - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

Table 38. How to connect Fibre Channel cables from file modules to the control enclosure.
File module
A File module 1
1 Fibre Channel slot 2, port 1
2 Fibre Channel slot 2, port 2
B File module 2
3 Fibre Channel slot 2, port 1
4 Fibre Channel slot 2, port 2
The Storwize V7000 control enclosure contains an upper and lower (inverted)
canister.
In isolating problems, be sure to review the labels on the rear of the systems for
exact port plugging.
Software detected problems via event codes:
If a software event code directed you to this procedure, use the Monitoring >
System page in the management GUI to identify the effected file module or refer
to the following procedure to determine the logical to physical mapping of the
event, then proceed to the physical hardware isolation procedures.
The isolation of Fibre Channel connections based on a single error event is not
simple. As Figure 41 on page 73 shows, there are two file modules attached to the
control enclosure; however, the logical host name of these systems does not map
directly to the connections. The logical host name of the file module depends on
which file module is used for initial USB flash drive installation. For example, in
Figure 41 on page 73, file module B can have a host name of mgmt001st001 if the
installation was initiated on that node or it might have a host name of
mgmt002st001 if the installation was initiated on the second file module. Each error
event is reported against the logical host name where the problem occurred.
For isolation of Fibre Channel connections, it is important with a single file module
that both Fibre Channel connections go to the same port number on both Storwize
V7000 node canisters. Port 1 always goes to node canister 1, and port 2 goes to
node canister 2.
Use the following table for correlating the error code with the physical connections,
then follow the procedures after the table for enabling the LED indicator on the
front of the file module.
Table 39. Error code port location mapping
Error code
Description
4B0800C
Link failure. Fibre
Channel adapter 1,
port 1 not up.
4B0801C
Link failure. Fibre
Channel adapter 1,
port 2 not up.
Control enclosure
C Control enclosure
5 Node canister 1 Fibre Channel port 1
7 Node canister 2 Fibre Channel port 1
C Control enclosure
6 Node canister 1 Fibre Channel port 2
8 Node canister 2 Fibre Channel port 2
Storage Node
File Module Fibre
Canister Fibre
Channel Location
Channel Port
PCI slot #2 – port 1
Node canister 1, port
(right port when
1. OR node canister
facing rear of system)
1, port 2.
PCI slot #2 – port 2
Node canister 2, port
(left port when facing
1. OR node canister
rear of system)
2, port 2.
Chapter 3. Getting started troubleshooting
75

Advertisement

Table of Contents
loading

Table of Contents