Removing And Replacing The Storwize V7000 Gen2 Expansion Canister - IBM Storwize V7000 Unified Problem Determination Manual

Table of Contents

Advertisement

10. Finish inserting the canister by closing both release levers so that both orange
11. The canister is correctly installed when the rear face of the canister is flush
12. Reattach each SAS cable into the port from which it was removed in step 5 on
Figure 81. Removing and replacing the Storwize V7000 Gen2 expansion canister
Replacing an expansion canister
This topic describes how to replace an expansion canister.
About this task
Attention: Even though many of these components are hot-swappable, they are
intended to be used only when your system is not active (no I/O operations). If
your system is powered on and processing I/O operations, go to the management
GUI and follow the fix procedures. Initiating the replacement actions without the
assistance of the fix procedures can result in loss of data or loss of access to data.
300
Storwize V7000 Unified: Problem Determination Guide 2073-720
latches click into place.
with the rear edge of the enclosure.
If the enclosure is powered on and the canister is correctly installed, the
canister starts automatically.
page 299.
a. Ensuring the SAS cable connectors are inserted with the pull tab to the
bottom of the connector, gently push the connector in until a slight click is
felt or heard.
b. Verify that the connector is fully inserted by gently pulling on it (not on
the tab).
You should not be able to remove it.
If the enclosure is powered on and the SAS connector is correctly inserted
into the port, the green SAS link LED above the port lights up.

Advertisement