IBM Storwize V7000 Unified Problem Determination Manual page 185

Table of Contents

Advertisement

3. Slide the file module out of the rack and remove the cover (see "Removing the
cover" on page 123). The LED on the system board near the connector for the
failing dual-motor hot-swap fan will be lit.
Attention: To ensure proper system cooling, do not remove the top cover for
more than 30 minutes during this procedure.
4. Grasp the dual-motor hot-swap fan by the finger grips on the sides of the
dual-motor hot-swap fan.
5. Rotate the air baffle up.
6. Lift the dual-motor hot-swap fan out of the file module.
7. Replace the dual-motor hot-swap fan within 30 seconds.
8. If you are instructed to return the dual-motor hot-swap fan, follow all
packaging instructions, and use any packaging materials for shipping that are
supplied to you.
Installing a hot-swap fan
The following procedure is for a Tier 1 customer replaceable unit (CRU).
Replacement of Tier 1 CRUs is your responsibility. If IBM installs a Tier 1 CRU at
your request, you will be charged for the installation. Service agreements can be
purchased so that you can ask IBM to replace these units.
About this task
For proper cooling, the file module requires that all three dual-motor hot-swap
fans be installed at all times.
Attention: To ensure proper file module operation, if a dual-motor hot-swap fan
fails, replace it immediately. Have a replacement dual-motor hot-swap fan ready to
install as soon as you remove the failed dual-motor hot-swap fan.
See System-board internal connectors for the locations of the dual-motor hot-swap
fan connectors.
To install any of the three replaceable fans, complete the following steps.
157
Chapter 4. File module

Advertisement

Table of Contents
loading

Table of Contents