Table 120. Upgrade error codes and recommended actions (continued)
Error
Code
Explanation
01A9
Unable to stop performance
collection daemon.
01AB
Internal upgrade error in
node_setup_system.
01B1
Management node replication
failed.
01B2
Unable to start performance
collection daemon.
01B3
Failed to copy upgrade package to
Storwize V7000.
01B4
Failed to start upgrade on Storwize
V7000 with the applysoftware
command.
01B5
Storwize V7000 multipaths are
unhealthy.
01B6
Storwize V7000 vdisks are
unhealthy as indicated by using the
lsvdisk command.
01B7
Failed to query status of Storwize
V7000 upgrade by using the svcinfo
lsupdate command.
Action
Contact IBM Remote Technical Support.
Contact IBM Remote Technical Support.
1. Follow the replication recovery
procedure. See Resolving issues
reported by lshealth for resolving the
management node replication failure.
2. Contact IBM Remote Technical
Support.
Contact IBM Remote Technical Support.
This could be caused by a number of
issues. Check Monitoring > Events under
both the block tab and the file tab on the
management GUI for an event that could
have caused this error and follow the
recommended action. If there is no
obvious event that could have caused
this error, refer to "Ethernet connectivity
from file modules to the control
enclosure" on page 68.
This could be caused by a number of
issues. Check Monitoring > Events under
both the block tab and the file tab on the
management GUI for an event that could
have caused this error and follow the
recommended action. If there is no
obvious event that could have caused
this error, refer to "Ethernet connectivity
from file modules to the control
enclosure" on page 68.
Check the Fibre Channel connections to
the system. Reseat Fibre Channel cables.
For more information, see Fibre Channel
connectivity between file modules and
control enclosure.
See Chapter 5, "Control enclosure," on
page 203.
This could be caused by a number of
issues. Check Monitoring > Events under
both the block tab and the file tab on the
management GUI for an event that could
have caused this error and follow the
recommended action. If there is no
obvious event that could have caused
this error, refer to "Ethernet connectivity
from file modules to the control
enclosure" on page 68.
Chapter 7. Recovery procedures
421

Advertisement

Table of Contents
loading