[Pr. PF34_Machine diagnosis function selection (*MFP)]

Initial value
00000000h
[Pr. PF34.0_Friction failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled (Automatic threshold setting)
2: Enabled (Manual threshold setting)
3: Threshold reset
When "2" is set, if the dynamic friction exceeds the set threshold, [AL. 0F7.2 Friction failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.1_Vibration failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled (Automatic threshold setting)
2: Enabled (Manual threshold setting)
3: Threshold reset
When "2" is set, if the vibration level exceeds the set threshold, [AL. 0F7.1 Vibration failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.2_Servo motor total travel distance failure prediction warning selection]
Initial value
0h
0: Disabled
1: Enabled
2: Servo motor total travel distance reset
When "1" is set, if the servo motor total travel distance + [Pr. PF58 Servo motor total travel distance offset] exceeds [Pr. PF53
Failure prediction - Servo motor total travel distance], [AL. 0F7.3 Servo motor total travel distance failure prediction warning]
will occur.
When "2" is set, the setting of the servo parameter will change to "1" automatically after the servo motor total travel distance
reset.
[Pr. PF34.5_Static friction failure prediction warning selection]
Initial value
0h
0: Disabled
1: Automatic threshold setting
2: Manual threshold setting
3: Threshold reset
When "2" is set, if the static friction exceeds the set threshold, [AL. 0F7.5 Friction failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
1 DETAILED LISTS OF SERVO PARAMETERS
80
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
00000000h to 01414234h
Setting range
0h to 3h
Setting range
0h to 3h
Setting range
0h to 2h
Setting range
0h to 3h
Setting method
Each axis
Supported software version
A0
Supported software version
A0
Supported software version
A0
Supported software version
A0
Supported software version
Refer to each detail No.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g series

Table of Contents