[Pr. Pb18_Low-Pass Filter Setting (Lpf)] - Mitsubishi Electric MELSERVO-J5 MR-J5-G Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 MR-J5-G Series:
Table of Contents

Advertisement

Setting value
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
[Pr. PB17.2_Notch depth selection]
Initial value
0h
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB

[Pr. PB18_Low-pass filter setting (LPF)]

Initial value
3141 [rad/s]
Set the low-pass filter.
Refer to the following table for the relation of setting values for the related servo parameter to the status of this parameter.
When [Pr. PA08.0 Gain adjustment mode selection] is set to "5" (Quick tuning mode), this servo parameter returns to the initial
value.
[Pr. PB23.1 Low-pass filter selection]
"0" (initial value)
"1"
"2"
1 DETAILED LISTS OF SERVO PARAMETERS
34
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Setting range
0h to 3h
Setting range
100 to 36000
Frequency [Hz]
342
339
336
333
330
327
324
321
318
315
313
310
307
305
302
300
297
295
292
290
288
285
283
Supported software version
A0
Setting method
Each axis
[Pr. PB18 Low-pass filter setting]
Automatic setting
Setting value enabled
Setting value disabled
Supported software version
A0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5 mr-j5w-g series

Table of Contents