General Data, Pm240-2 - 690 V - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converters, chassis and wall/panel mounted devices with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

10.2.2.5

General data, PM240-2 - 690 V

Property
Line voltage
Output voltage
Input frequency
Output frequency
Power factor λ
Inrush current
Overvoltage category acc.
to EN 60664-1
Pulse frequency
Short-circuit current rating
(SCCR)
Electromagnetic compati-
bility according to IEC/EN
61800-3
Braking methods
Degree of protection ac-
cording to EN 60529
Ambient temperature for
Ambient conditions accord-
ing to EN 60721-3-3
Temperature during stor-
age according to EN
60721-3-3
Cooling air
Relative humidity
Pollution according to EN
61800-5-1
Shocks and vibration ac-
cording to EN 60721-3-1
Installation altitude
Approvals
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB
Version
3 AC 500 V ... 690 V -20% ... +10 %
3 AC 0 V ... 0.95 x input voltage (max.)
50 Hz ... 60 Hz, ± 3 Hz
0 ... 550 Hz, depending on the control mode
> 0.9
< LO base load input current
The inverter insulation is designed for surge voltages according to overvoltage Category III.
2 kHz (factory setting), can be adjusted to 4 kHz
The output current is reduced if you increase the pulse frequency.
≤ 65 kA rms
Devices with integrated filter are suitable for Category C2 environments.
DC braking, compound braking, dynamic braking with integrated braking chopper
IP20; must be installed in a control cabinet
LO base load power without derating:
HO base load power without derating:
LO/HO base load power with derating:
Details see Section Restrictions for special ambient conditions (Page 428).
For the maximum permissible ambient temperature, also observe the permissible ambient
temperatures for the Control Unit and possibly operator panel (IOP or BOP-2) .
Protected against damaging chemical substance, according to environmental Class 3C3
-40 °C ... +70 °C
clean and dry air
< 95% - condensation not permissible
suitable for environments with degree of pollution 2
Long-term storage in the transport packaging according to Class 1M2
Transport in the transport packaging according to Class 2M3
Vibration in operation according to Class 3M2
without derating:
up to 1000 m above sea level
with derating:
up to 4000 m above sea level
Details see Section Restrictions for special ambient conditions (Page 428).
cULus, CE, C-tick, SEMI F47, KCC,WEEE, RoHS, EAC
10.2 Technical data, Power Modules
-20 °C ... +40 °C
-20 °C ... +50 °C
-20 °C ... + 60° C
Technical data
403

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120cSinamics g120p

Table of Contents