Backing up data and series commissioning
7.1 Backing up and transferring settings using a memory card
Manually backing up
Preconditions
• The inverter power supply has been switched on.
• No memory card is inserted in the inverter.
Procedure with STARTER
Proceed as follows to back up your settings on a memory card:
1. Go online.
2. Press the "Copy RAM to ROM" button
3. In your drive, select "Drive Navigator".
4. Select the "Commissioning" button.
312
.
Converter with CU230P-2 Control Units
Operating Instructions, 04/2015, FW V4.7 SP3, A5E34257946B AB