Motor Data Identification - Induction Motor - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Servo control
3.12 Motor data identification
Table 3-9
Type plate data
Induction motor
p0304 rated voltage
p0305 rated current
p0307 rated power
p0308 rated power factor (cos ϕ)
p0310 rated frequency
p0311 rated speed
p0322 maximum motor speed
p0353 motor series inductance
p0400ff encoder data
Since the type plate data contains the initialization values for identification, you must ensure
that it is entered correctly and consistently to enable the above data to be determined.
Parameters to control the MotID
The following parameters influence the MotID:
Table 3-10
Parameters for control
Static measurement (motor data identification)
p0640 current limit
p1215 Motor holding brake configuration
p1909 Motor data identification control word
p1910 Motor data identification, stationary
p1959.14/.15 clockwise/counter-clockwise direction or
rotation permitted
Note:
If a brake is being used and is operational (p1215 = 1, 3), then the stationary measurement with closed brake is carried-
out. If possible (e.g. no hanging/suspended axis), we recommend that the brake is opened before the MotID (p1215 = 2).
This also means that the encoder size can be adjusted and the angular commutation calibrated.
3.12.1

Motor data identification - induction motor

Induction motor
The data are identified in the gamma equivalent circuit diagram and displayed in r19xx. The
motor parameters p0350, p0354, p0356, p0358 and p0360 taken from the MotID refer to the
T equivalent circuit diagram of the induction machine and cannot be directly compared. This
is the reason that an r parameter is listed in the table, which displays the parameterized
motor parameters in the gamma equivalent circuit diagram.
94
Permanent-magnet synchronous motor
p0304 rated voltage
p0305 rated current
p0307 rated power (alternative p0316)
p0311 rated speed
p0314 motor pole pair number
or p0315 motor pole pair width
p0322 maximum motor speed
p0323 maximum motor current
p0353 motor series inductance
p0400ff encoder data
rotating measurement
p0640 current limit
p1082 Maximum speed
p1958 motor data identification ramp-up/ramp-down time
p1959 Rotating measurement configuration
p1960 Rotating measurement selection
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4