Monitoring module

6.6.1

Integration into the overall system

The monitoring module contains an electronic power supply and central moni-
toring functions, which are required to operate the drive modules.
6.6.2

Technical data (supplement to the general technical data)

Table 6-16
Power loss
Rated supply voltage
Alternatively, rated supply voltage
DC link
Current consumption
Type of cooling
Weight
Assessment factor for the electronic points
(EP)
Assessment factor for the gating points (AP)
The cross–section that can be connected to
the P600, N600, X131 terminal block
Reader's note
For an overview of the interfaces, refer to Section 6.2.1, Table 6-1 in the column
"Terminals used" under monitoring module.
For operation of the monitoring module only on the DC link, without AC power
supply, 1000 μF per monitoring module must be observed for the loading limit of
the line supply.
This capacity is not included in the calculation of the permitted number of
pulsed resistors, because they are de–coupled using diodes.
© Siemens AG 2012 All Rights Reserved
SIMODRIVE 611 Configuration Manual (PJU) – 02/2012 Edition
Technical data, monitoring module
70 W
3–ph. 400 V – 10% up to 480 V AC + 6%
600/625/680 V DC
for 3–ph. 400 V AC: approx. 600 mA
Natural ventilation
approx. 5 kg
Max. 8
Max. 17
S
S
6 Infeed Modules
6.6 Monitoring module
2
Max 10 mm
for cables with
conductor end sleeves
2
Max 16 mm
for cables with
pin–type cable lug