Installation Checklist

Smart Hub Checks:
Is the smart hub properly mounted to either a wall stud or wall?
1
NOTE: Do not mount on equipment or ductwork.
Is communication status LED (green) visible when hinged cover is closed?
2
NOTE: When LED is active it indicates that 24VAC is present at the smart hub. It also indicates communication is active between smart
hub and HD Display.
3
Is blinking communicating green LED seen (located in center of smart hub) when cover is open?
4
Are all terminal wiring properly connected and tight?
5
Are jumpers set to proper equipment type and number of stages?
When required, is either or both the discharge (DATS) and outdoor air temperature (OATS) sensors properly connected and isolated
6
when used?
1
Are all terminal wiring properly connected and tight?
1
Is the HD Display properly placed and connected to subbase?
2
Are all terminal wiring properly connected and tight on subbase?
Is the screen blank after initial power-up?
3
NOTE: The HD Display may take up to three minutes before anything appears on the screen due to a HD Display low battery condition.
HD Display battery charging only occurs when connected to the subbase.
1
Is the Wi-Fi connected?
2
Can the homeowner access the consumer portal (www.myicomfort.com) from either a PC or tablet?
3
Has the homeowner downloaded the Lennox Thermostat application from either Google Play or IOS App Store to their mobile devices?
4
Is the Lennox Dealer account number or your main shop phone number been added to the dealer information screen?
Has a complete system test been run? If not, from the HD Display home screen go to settings > advanced settings > view dealer
5
control center > and select tests.
HD Display Subbase Checks:
HD Display Checks: