P
E
OWER OVER
Parameter
Admin
Oper
Power (mWatt)
Power (used)
Priority
show power mainpower
Use this command to display the current power status for the switch.
Command Mode
Privileged Exec
Example
Console#show power mainpower
Unit 1 Mainpower Status
Maximum Available Power : 375 watts
System Operation Status : on
Mainpower Consumption
Software Version
Console#
Parameter
Maximum Available
Power
System Operation
Status
Mainpower
Consumption
Software Version
4-96
C
THERNET
OMMANDS
Table 4-27 show power inline status parameters
Description
The power mode set on the port (see power inline on
page 4-93)
The current operating power status (displays on or off)
The maximum power allocated to this port (see power inline
maximum allocation on page 4-93)
The current power consumption on the port in milliwatts
The port's power priority setting (see power inline priority on
page 4-94)
Table 4-28 show power mainpower parameters
Description
The available power budget for the switch (see power
mainpower maximum allocation on page 4-91)
The current operating power status (displays on or off)
The current power consumption on the switch in watts
The version of software running on the PoE controller
subsystem in the switch. This software can be updated using
the copy file controller command (see page 4-82).
: 15 watts
: Version 0x1B64, Build 0x07