Configuration; Resetting The Switcher - Extron electronics PVS 407D User Manual

Polevault digital switcher
Hide thumbs Also See for PVS 407D:
Table of Contents

Advertisement

Configuration

The PVS 407D switcher can be controlled by a MediaLink Controller (MLC) or by an
RS-232 device acting through the MLC. Alternatively, the switcher can be set up and
controlled via a host computer or other device (such as a control system) attached to the
front panel USB connector or direct connection to the Ethernet, or to the rear panel
RS-232 remote port of the switcher.
The control device (host) can use either the SIS commands or use the Extron Product
Configuration Software (PCS) program.
NOTE: See the SIS Communication and Control section, starting on page 18, for a full
Firmware updates (using Firmware Loader or PCS) can be made via the front panel USB
port or a TCP/IP connection over the network.

Resetting the Switcher

The switcher can be reset to the factory defaults using PCS software or SIS commands,
when connected via the front panel USB, rear panel RS-232, or TCP/IP (LAN connection).
The reset button on the front panel (see
switch that allows the user to put the switcher into any one of three different reset modes.
The PVS 407D switcher reset modes are:
list of the relevant SIS commands
Mode 1: If the reset button is held down while the switcher is being powered up, the
switcher runs the base factory firmware instead of any newer version that was loaded
after it shipped.
Mode 4: If the reset button is held down long enough for the
twice (about 6 seconds), then released and momentarily pressed again (within 1
second), the switcher resets all of its IP settings including IP address, subnet mask,
gateway address, and port maps. In addition, DHCP is turned off.
Mode 5: If the reset button is held down long enough for the
three times (about 9 seconds), then released and momentarily pressed again (within 1
second), the switcher resets all its settings (switcher AV & IP settings) back to factory
default condition. All files (including audio files) are removed/ cleared. This reset mode
SIS command
is equivalent to
NOTES:
If the second momentary press does not occur within 1 second, the reset
procedure is aborted.
SIS commands
ZXXX, ZY, and ZQQQ
wallplate(s).
It takes approximately 4 seconds for the connected wallplate(s) to fully boot
up after a reset.
figure
7,
, on page 9) is a small recessed
B
ZQQQ.
resets also reset the connected
PVS 407D Switcher • Operation
Status LED
to blink
Status LED
to blink
11