Summary of Contents for Extron electronics PVS 405D
Page 1
Installation Guide PoleVault System PoleVault Digital Switcher Systems featuring the PVS 405D Switcher Includes installation details for the PoleVault (PMK 560), WallVault (WMK 160 and USFM 100), and PlenumVault (PVM 220) Mounting Kits. 68-2380-01 Rev. A 03 14...
Safety Instructions Safety Instructions • English Инструкция по технике безопасности • Русский WARNING: This symbol, , when used on the product, is intended to ПРЕДУПРЕЖДЕНИЕ: Данный символ, , если указан alert the user of the presence of uninsulated dangerous voltage within the на...
Conventions Used in this Guide Notifications The following notifications are used in this guide: DANGER: A danger indicates a situation that will result in death or severe injury. WARNING: A warning indicates a situation that has the potential to result in death or severe injury.
Stage 4: (PVM 220) ............11 Installing the Switcher Mounting System 42-230-03 PLS 210D ........11 and the PVS 405D ..........39 42-231-03 PLS 410D ........11 A. PoleVault System Items Not Included ........12 (PMK 560 Pole Mount Kit) ......40 Installation Tools ...........
Page 6
B4. Cable the switcher ......... 46 Stage 5: Configuring the B5. Final Installation ........46 PVS 405D Switcher ........... 61 C. WallVault System 1. Configure the Switcher — (USFM 100 Short Throw Wall Mount Kit) ..47 PCS Product Configuration Software C1.
Introduction Overview This guide covers the installation of the Extron PoleVault Digital System, and also the installation methods for each type of WallVault and PlenumVault enclosure. NOTE: PoleVault, WallVault, and PlenumVault Digital systems use the same digital PVS switcher, input source AV devices, control device, and ceiling speakers. However, the systems have different mounting enclosures, (PMK 560, USFM 100, WMK 160, and PVM 220), depending on the system type.
Before You Begin — Planning the Installation Before installation is started, you must consider several major factors to ensure that the installation process is as smooth and trouble free as possible, and so that the final finished project meets the needs of the customers, users, audiences, and installer. The installation considerations on the following pages, though not comprehensive, should be consulted to help ensure that key installation aspects have been considered.
Page 10
Ceiling and wall type (important in assessing the hardware needed) • Ceiling type: dropped, spline, hard lid, and similar. Structural type (wood, concrete, • trusses), plenum or non-plenum Wall type: drywall, cement, brick. • WARNING: Structural ceiling failure could cause death serious injury or death.
Page 11
Location of MediaLink Controller and Wall Plates Forward and side reach (for full details refer to a copy of ADA Standards for • Accessible Design, Sections 307 and 308, for ADA requirements). Location of source devices: • Desk, table, or rack mounted, and proximity to proposed transmitter location (wall, podium, or furniture) Cabling obstacles: •...
(1) MLC IR, 50 ft PMK 560 Pole Mount Kit (1) HDMI Micro, 3 ft The PVS 405D may come (4) M6 x 40 mm screws pre-installed on the PMK 560 (4) M5 x 40 mm screws (4) (1) Snap-in trim piece...
PoleVault Digital System Devices and Hardware, cont’d PoleVault Digital System 42-207-03 or 42-208-03 FF 120 PVT SW HDMI RGB D MLC 104 IP Plus PVS 405D This item may come pre-installed on the PMK 560 DISPLAY AUDIO AUDIO IN PVS 405D...
Items Not Included The following items are not included in the systems. However, input and display devices are essential parts of the system, and at any installation they may vary depending on their use. This list suggests various devices that may be used. Projector (or display device) •...
Optional Items The optional Extron products suggested below can be added to or substituted for items in the standard Digital PoleVault System. Some of these items may also be suitable for the Digital WallVault or PlenumVault Sytems. Optional accessories: • Wall mount speakers (for example, SI 26) or extra ceiling speakers MLC 104 IP Plus DV+ controller (includes DVD/VCR IR control) MLC 104 IP Plus L controller (with lectern faceplate)
Page 20
PoleVault Digital Systems • Introduction...
Installation Overview This section outlines the basic steps for installing the PoleVault System. An outline and checklist of the stages (Stages One through Five), listing the relevant steps within each stage, is given on pages 16 and the rear cover. A fully detailed description of these steps is given in the five corresponding sections.
Install the speaker on the drop ceiling (page 36). Terminate the speaker cable for the PVS switcher (page 38). Stage 4A — Install the PMK 560 and PVS 405D. Install the PMK 560 base plate (page 40) Pull the cables (at the switcher location) (page 41).
Stage 1: Installing the Screen and Projector Stage 1 Involves installing the three pieces of hardware shown below. PCM 340 Projector Drop Ceiling Mount Where it goes: Attaches to a structural ceiling, • 1-gang and 2-gang Accessory Mounting rests on the suspended ceiling. Points (Power Sockets) Base PCM 340...
1. Mark Screen Location. TIPS: When marking the location of screens, • devices, or the site for installing transmitters and MediaLink control devices, use painters Ä Mark the screen location. tape to avoid wall surface damage. When marking the center line of the •...
Page 25
d. Using a 3/32 inch hex wrench, back out the set screws on the top portion of the adjuster plate (see in the image below) of the UPB 25. Screw the plate onto the base of the pipe. Align it so the security flange is at the rear Set Screws (2) Loosen the four adjuster plate Adjuster...
Page 26
Pivot the arms so that they extend towards the center of the projector (see the figure at right). Adjust the arms as needed for your projector model. NOTE: Avoid overlapping the arms where possible. Washer vi. Pivot arms towards center of projector. With the security flange towards the rear of vii.
Check for stress on the arms. To do this loosen the mounting screws (do not remove). Loosen the screw and adjust If the arm or the barrel lifts, this indicates the barrel height to reduce torque on the arms and bracket. stress on the arm.
4. Cut the Ceiling Tile. a. Mark the location of the PCM 340 on the X" T-frame. This aids putting it back in the correct location when the tile is replaced. Mark the screen direction on back TIP: Y" of the tile (for example with an arrow or “to front”) to help orientation of tile when T-bar replacing it after cutting...
6. Finish Projector Drop Ceiling Mount Installation. a. Detach the projector bracket and projector from the adjuster plate. DO NOT remove the projector bracket from the projector. b. Unscrew the adjuster plate from the mounting pole. c. Loosen the pipe adapter set screws on the PCM 340 and the pipe location screw and remove the mounting pole, then loosen the T-frame securing screws and remove the PCM...
7. Secure the Projector Drop Ceiling Mount to the Ceiling. a. Attach the four turnbuckles to the base plate, one at each corner. WARNING: May result in serious injury. DO NOT rest or lean on the mounting plate or suspended ceiling when attaching turnbuckles, tie wire, or when drilling into the ceiling.
8. Install the Electrical Box (If required). WARNING: Improper installation may result in electrical shock or serious injury. All electrical installation should be performed by qualified personnel in accordance with local and national building codes, fire and safety codes, and local and national electrical codes.
Page 32
PoleVault Digital Systems • Installation — Stage 1 (Screen and Projector)
The PoleVault Digital System incorporate EDID Minder. This allows the transmitter to communicate the • appropriate EDID information to the source, ensuring correct video output resolution. The EDID settings on the PVT wallplates are set during switcher configuration. See the PVS 405D • PoleVault Digital Switcher User Guide (available at ),or the PCS Help file for setup and www.extron.com...
Page 34
Cabling for the Wallplates and MediaLink Controller PVT transmitter installation Sheilded twisted pair (STP) signal transmission cables • STP201P cable, 35 ft (connects PVT input wallplates to PVS 405D switcher) 26-696-35 MLC 104 IP Plus installation MLC power and RS-232 control cable •...
NOTE: The installation must conform to national and local building and electrical codes, and UL requirements. See the device user guides for details. 1. Install the Mud Rings. NOTE: These devices can be installed using the Wall supplied mud ring or a wall box. If installing a box, allow enough depth for the plate and the cables.
STP cables for signal transmission from the • AV wallplates to the PVS 405D NOTES: Maximum distance from the • PVS 405D to the Wallplate is 150 feet. STP cables supplied are terminated to • the TIA 568B standard. PoleVault switcher communication cable •...
R (black wire), and L (red wire). The other input devices at each location. end will be connected to the “Line Out” connection on the PVS 405D switcher. This option is available only with PVT SW HDMI RGB D wallplates.
Ground all devices. MLS PWR RS-232 12V NOTE: The MLC 104 IP Plus is powered from the PVS 405D associated power supply. Ü Connect the MLC 104 IP Plus to the PVS 405D Switcher and Power Supply. PoleVault Digital Systems • Installation — Stage 2 (Wallplates and MLC)
Page 39
DIGITAL RS-232/IR COMM LINK RS-232 MLC 104 IP Plus Right Side Panel NOTE: Connect to the PVS 405D Ethernet ports as follows: 1. TCP/IP network 2. MLC controller 3. Optional Network Device ó Connect to the LAN using a CATx cable.
Page 40
The connections between the MLC 104 IP Plus and the PVS 405D switcher should look like the figure below. PVS 405D INPUTS OUTPUT AUDIO OUT AMPLIFIED AUDIO OUT PAGING LAN 1 LAN 2 LAN 3 SENSOR DO NOT GROUND...
T-rails (2) Where it goes: Installs in ceiling tiles at a predetermined location for best acoustics. • Connects to the switcher. What it does: Receives and outputs audio signal from the PVS 405D switcher. • Cabling for the Speakers Speaker Installation:...
NOTE: The installation must conform to national and local electrical codes, and UL requirements. See the device guide for details. 1. Cut Ceiling Tile. a. Remove the ceiling tiles where the speakers are to be installed. For ease of working on the speaker TIP: when it is replaced on the T-frame, remove adjacent tiles.
Page 43
Repeat steps 1 and 2 for each speaker that needs to be installed, connecting the speakers according to the system preferred (for example, in parallel, see page 38). If you wish to install an optional seismic/ safety cable, at each speaker location do the Anchor this end to a following: lag eye bolt screwed...
NOTE: By default, the amplifier is set for dual mono output. Use the software or Extron Special Instruction Set (SIS) commands to change the setting to stereo if desired. For full details, see the PVS 405D User Guide, available online at www.extron.com...
Stage 4 Involves installing the switcher mounting system and the PVS 405D Digital Switcher. This stage is divided into four sections based on the system type. Each system mounts the PVS 405D switcher and associated power supply using a specific mounting kit.
Where it goes: Attaches to slotted pipe, above the projector and close to the drop ceiling. • What it does: Supports and hides the installed PVS 405D switcher and power supply from view. • A1. Install the PMK 560 Base Plate.
NOTE: Do not thread any high voltage To Projector power cabling, such as power supply or projector power cords, through the Switcher and Projector Cable Overview projector pipe. This violates National Electrical Code. PoleVault Digital Systems • Installation — Stage 4 (PMK 560 and PVS 405D)
Place the included tie wrap around the HDMI connector and the LockIt lacing bracket and tighten as shown in the images at right. Secure HDMI Cable with LockIt Bracket PoleVault Digital Systems • Installation — Stage 4 (PMK 560 and PVS 405D)
A4. Finish Installing the Mounting Kit. CAUTION: The PoleVault signal transmission method is specific for PVS 405D switcher working with PVT wallplates. DO NOT connect the input ports to an MTP system or to an LAN or data transmission system.
(1) WMK 160 Cover Where it goes: Installs onto a wall close to the projector. • What it does: Supports and hides from view the installed PVS 405D switcher, power supply, and any • installed optional accessories. B1. Install the WMK 160 Base Plate...
Secure to the standoffs with 4-40 x 3/16 inch screws. Attach switcher to the mounting plate and secure both to the base plate. PoleVault Digital Systems • Installation — Stage 4 (WMK 160 and PVS 405D)
MTP system or to an LAN or data transmission system. B5. Final Installation. Place the cover onto the WMK 160 base plate and tighten down the screws to secure the cover. PoleVault Digital Systems • Installation — Stage 4 (WMK 160 and PVS 405D)
Plastic Enclosure Cover Where it goes: Installs onto a wall close the short throw projector location. • What it does: Supports the short throw projector and hides from view the installed PVS 405D switcher, • power supply, and any installed optional accessories.
Secure the plate to the switcher using the two 4-40 x ¼ inch pan head screws. PoleVault Digital Systems • Installation — Stage 4 (USFM 100 and PVS 405D)
2400 Raceway Option V700 Conduit Option Signal Cable Access Cutout Option Options for Running the Cables to the USFM 100 PoleVault Digital Systems • Installation — Stage 4 (USFM 100 and PVS 405D)
¼-28 x ¾ inch screw. Screw Screws and Washers Phillips Pan Head Screws Set Screw USFM 100 Base Plate. PoleVault Digital Systems • Installation — Stage 4 (USFM 100 and PVS 405D)
Page 57
Do not thread the projector power cable through the boom arm or mounting pipe. Threading it through the arm or the pipe violates national electrical regulations. PoleVault Digital Systems • Installation — Stage 4 (USFM 100 and PVS 405D)
Where it goes: Installs onto a T-grid , within the air-handling space above a suspended ceiling near • (within 50 feet) of the projector location. What it does: Supports and hides from view the installed PVS 405D switcher, power supply, and any • installed optional accessories.
Thread the looped end of the suspension cable though the bolt eyehole, pass the rest of the cable through the loop and tighten. Allow each cable to hang down. PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
Repeat for each corner. e. Adjust the cable tension through all locks, making each cable taut without lifting the PVM 220 off the T-grid. Pass Cable through the Cable Locks. PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
(see figure at right). module from the PVM 220 enclosure. b. Unscrew the two screws on the corners and detach the outer cover. Cabling the Power Module PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
Tighten down the cable grip until the cables are held firmly. Avoid damaging or bending cables at too sharp an angle. PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
(see figure on Bottom of Door (Door Locks) page 58). Example: 24 x 24 inch Ceiling Tile Cut the ceiling tile PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
Wire the fan controller for manual on and off. c. Connect and dress the other device cables as needed, providing enough slack to open and close the access door. PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
(see the figure at right). For full safety secure both latches. To secure the latch from opening tighten the set screw onto the latch. Secure the door latch. PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
Page 66
PoleVault Digital Systems • Installation — Stage 4 (PVM 220 and PVS 405D)
Configuration Software Program a. Download and install the Extron Product Configuration Software (PCS) program onto the PC that is to be connected to the PVS 405D. ü b. Connect the switcher to the PC via the front Select online device or emulation mode (below).
2. Configure the System — Global Configurator. a. Download and install the Extron Global Configurator (GC) configuration program (available at ) on the PC. www.extron.com b. Ensure the PC and the MLC 104 IP Plus are connected to the LAN and powered on. NOTE: Alternatively, connect a 2.5 mm TRS configuration cable (part number...
3. Test the System. a. Connect all the input devices (PC, DVD, document camera, and, where desired, LAN cables, and so forth) to the transmitters and power up the input devices. Check that power and signal are present at the transmitters. The LEDs light red when only power is present and light green when power and a signal are present.
Page 70
VoiceLift input Level has been NORMAL properly adjusted adjustments may not be required. SIGNAL Signal threshold -20 dBV (-18 dBu) ® Adjust the audio levels on the PVS 405D. PoleVault Digital Systems • Installation — Stage 5 (Configuration)
g. Where installed, it may be necessary to adjust the sensitivity of the Priority Paging system. During a test transmission of the paging system rotate the Paging Sensor encoder until program audio is no longer heard from the PoleVault speakers. See the Priority Page Sensor Installation Instructions, or page 67 of this guide, for full details.
Speech is picked up by the pendant microphone worn by the teacher and is transmitted via wireless from a base station receiver and the PVS 405D to the installed ceiling speakers.
T IN M AX Input Typical PPS 35 paging system with PVS 405D switcher. The Extron PPS 35 Priority Page Sensor works with the PVS 405D PoleVault Digital Switcher only and is an optional part of a PoleVault, a PlenumVault, or a WallVault system.
3. Connect the end of the three-wire cable to the Paging Sensor port on the rear panel of the PVS 405D. Wire the connector as shown at right. Attach the Sensor to the front grille of a speaker 4. Test and configure the PPS 35 using the...
Extron PVS 405D Paging System PoleVault Switcher Typical PPS 25 paging system with PVS 405D switcher. The Priority Page Sensor Kit momentarily silences classroom audio whenever a page is made from a public address (PA) system. For detailed information, see the Priority Page Sensor Kit Installation Instructions, supplied with the device.
Installation Procedure WARNING: Risk of serious personal injury if installation is not done correctly. All structural steps, anchoring, and electrical installation should be performed by qualified personnel in accordance with local and national building codes, fire and safety codes, and/or local and national electrical codes.
Page 77
Page Sensor port captive screw connector (use the + VOICELIFT VOICELIFT and - poles) on the rear panel of the PVS 405D. INPUT 5 INPUT 5 Polarity need not be observed. 7. If a junction box is being used in a plenum space, ensure the sensor and all wires fit inside the box (as shown at right).
3. If the program fails to mute the classroom audio Sensitivity Adjustment Encoder during a page, turn the Sensitivity adjustment, on the front panel of the PVS 405D, clockwise. 4. If the classroom audio is muted without a page occurring, turn the Sensitivity adjustment counterclockwise.
Install the speaker on the drop ceiling (page 36). Terminate the speaker cable for the PVS switcher (page 38). Stage 4B — Install the WMK 160 and PVS 405D. Install the WMK 160 base plate (page 44) Install the switcher onto the base plate (page 45).
Install the speaker on the drop ceiling (page 36). Terminate the speaker cable for the PVS switcher (page 38). Stage 4C — Install the USFM 100 and PVS 405D. Install the USFM 100 base plate (page 48) Install the switcher onto the base plate (page 48).
Install the speaker on the drop ceiling (page 36). Terminate the speaker cable for the PVS switcher (page 38). Stage 4D — Install the PVM 220 and PVS 405D. Remove the device mounting plate from the access door (page 53) Remove ceiling tile and install suspension cables (page 53).
Page 82
Optional Accessory Installation VoiceLift System (page 66) Priority Page Sensor PPS 35 (page 67) Priority Page Sensor Kit PPS 25 (page 69). The pages listed above contain instructions for installing the PlenumVault Digital System. Where possible, line drawings and photos from an actual installation are used to clarify some of the steps discussed in the text. Most images have a number corresponding to the step that is being described (for example, Ñ).
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.