Omron CS1W-LC001 Operation Manual page 42

Loop control unit
Table of Contents

Advertisement

Outline
Category
Type
Operation
Pulse Train
Block
Operation
(continued)
Others
Sequence
Operation
Contact Type
Control
Target
Sequential Control
Node
Send to
Terminal
Computer
22
Block
Block name
model
184 Accumulator for
accumulated value
input
185 Contact
input/Accumulated
value output
186 Accumulated
Value
Input/Contact
Output
192 Analog/Pulse
Width Converter
201 Contact Distributor Connect contact signals between function blocks in
202 Constant
Comparator
203 Variable
Comparator
205 Timer
206 ON/OFF Timer
207 Clock Pulse
208 Counter
209 Internal Switch
210
Level Check
221 ON/OFF Valve
Manipulator
222 Motor Manipulator Manipulates and monitors motor operation.
223 Reversible Motor
Manipulator
224 Motor Opening
Manipulator
301 Step Ladder
Program
401 DO to Computer
402 AO to Computer
403 1-Block Send
Terminal to
Computer
404 4-Block Send
Terminal to
Computer
Function
Converts 4-digit accumulated value signals to 8
digits.
Counts low-speed contact pulses, and outputs 8-
digit accumulated signals.
Converts 4-digit accumulated value signals to low-
speed contact pulses before they are output.
Changes the ON/OFF duration ratio in a constant
cycle duration so that it is proportional to the analog
signal.
a 1:1 connection.
Compares up to eight sets of analog signals and
constants, and outputs the comparison results as
contacts.
Compares up to eight pairs of analog signals, and
outputs the comparison results as contacts.
2-stage output-type addition timer for forecast
values and reached values. Can also output the
present value.
Timer for performing ON-OFF operation at preset
ON and OFF times.
Outputs clock pulses that turn ON for one operation
cycle only at each set time.
2-stage output type addition timer for forecast values
and arrival values. Can also output the current
value.
Temporary storage contact for accepting relays in
the Step Ladder Program block.
(Note: One internal switch is already allocated as
"temporary storage" in CX-Process Tool.)
Checks the level of an analog input for eight levels
and outputs contacts according to the level. The
level number is also output via an analog output.
Manipulates and monitors ON/OFF valves with
open/close limit switches.
Manipulates and monitors reversible motor
operation.
Inputs a target opening, and manipulates an electric
positional-proportional motor.
Performs logic sequence and step progression
control.
Sends 128 contacts to the send-to-computer area.
When CX-Process Monitor is used, the contact
signals to be monitored are connected to this
function block.
Sends 16 analog values to the send-to-computer
area. When CX-Process Monitor is used, the analog
signals to be monitored are connected to this
function block.
Sends a specified 1 block to the send-to-computer
area. When CX-Process Monitor is used, the 1 block
to be monitored are connected to this function block.
Sends a specified 4 block to the send-to-computer
area. When CX-Process Monitor is used, the 4 block
to be monitored are connected to this function block.
Section
1-1
Allocatable
block
address
100 to 349
(Note: 349
is an
internal
switch in
CX-
Process
Tool (One
Block
Model 209
is already
allocated
as the
default.))
400 to 499
501 to 532

Advertisement

Table of Contents
loading

Table of Contents