Outline
Category
Type
Operation
Functions
Block
(continued)
Time
Function
Signal
Selection/
Switching
ITEM
Settings
Block
Block name
model
131 Square Root
132 Absolute Value
133 Non-linear Gain
(Dead Band)
134 Low-end Cutout
135 Segment
Linearizer
136 Temperature And
Pressure
Correction
141 First-order Lag
143 Rate-of-change
Limit
145 Moving Average
147 Lead/Delay
148 Dead Time
149 Dead Time
Compensation
150 Accumulator for
instantaneous
value input
151 CPU Unit Running
Time Accumulator
153 Time Sequence
Data Statistics
155 Ramp Program
156 Segment Program Segment program setter setting the output values
157 Segment Program
2
161 Rank Selector
162 Input Selector
163 3-input Selector
164 3-output Selector Outputs one analog input signal in three switched
165 Constant Selector Selects 8 preset constants by the contact signal.
166 Constant
Generator
167 Ramped Switch
171 Constant ITEM
Setting
172 Variable ITEM
Setting
174 Batch Data
Collector
182 Accumulated
Value Input Adder
183 Accumulated
Value Analog
Multiplier
Function
Performs square root extraction (with low-end
cutout) on single analog signals.
Performs non-linear (3 gain values) operation on
single analog signals. Analog signals can also set as
a dead band (with different gap).
Outputs the absolute value of single analog signals.
Sets output to zero close to the zero point of single
analog signals.
Converts single analog sigals to 15 segments before
the signals is output.
Performs temperature and pressure correction.
Performs first-order lag operation on single analog
signals.
Performs rate-of-change restriction on single analog
signals.
Performs moving average operation on single
analog signals.
Performs lead/delay operation on single analog
signals.
Performs dead time and first-order lag operations on
single analog signals.
Used for Smith's dead time compensation PID
control
Accumulates analog signals, and outputs 8-digit
accumulated value signals.
Accumulates the operating time, and outputs the
pulse signal per specified time.
Records time sequence data from analog signals
and calculates statistics, such as averages and
standard deviations.
Ramp program setter for combining ramps for time
and hold values.
with respect to time.
Segment program setting with wait function for
setting the output values with respect to time
Selects the rank of up to 8 analog signals.
Selects the specified analog signals specified by the
contact signal from up to 8 analog signals.
Selects and outputs one of three analog input
signals.
direction.
Outputs 8 independent constants.
Creates a ramped switch based on two analog
inputs or constants.
Writes the constant to the specified ITEM at the
rising edge of the send command contact.
Writes the analog signal to the specified ITEM at the
rising edge of the send command contact.
Stores each of max. 8 analog inputs to buffer by a
certain timing within sequential processing.
Adds up to four accumulated value signals.
Multiplies analog signals by the accumulated value
signals.
Section
1-1
Allocatable
block
address
100 to 349
(Note: 349
is an
internal
switch in
CX-
Process
Tool (One
Block
Model 209
is already
allocated
as the
default.))
21