Advertisement

The SERIAL 2 TO UUT serial data port connects a UUT to a PC or terminal with the
5502A (see Figure 1-2). This "pass-through" configuration removes the requirement for
two COM ports at the PC or terminal. A set of four commands control the operation of
the SERIAL 2 TO UUT serial port. See Chapter 6 for a discussion of the UUT_
commands.
CALIBRATOR
5502A
SERIAL 2
TO UUT port
CALIBRATOR

Remote Operation (IEEE-488)

The rear-panel IEEE-488 port is a fully programmable parallel interface bus that
complies with standard IEEE-488.1 and supplemental standard IEEE-488.2. When the
Calibrator is used by remote control of an instrument controller, the Calibrator operates
exclusively as a "talker/listener." You can write your own programs with the IEEE-488
command set or run the optional Windows-based MET/CAL Plus software. See Chapter
6 for a discussion of the commands available for IEEE-488 operation.
SERIAL 1 FROM HOST port
RS-232 Remote Operation using the
SERIAL 1 FROM HOST port
SERIAL 1 FROM HOST port
5502A
RS-232 Remote Operation using the
SERIAL 1 FROM HOST and
SERIAL 2 TO UUT ports
Figure 1-2. RS-232 Remote Connection
Introduction and Specifications
COM port
PC or Terminal
COM port
PC or Terminal
Unit Under Test
1
Operation Overview
gvx002.eps
1-7