Z_RTMWR_J, Z_RTMWR_U
5.4.13

RTMWR instruction

Z(P)_RTMWR_J
Z(P)_RTMWR_U
Structured ladder
Z_RTMWR_J
EN
ENO
Jn*
d1
n1
d2
n2
n3
Input argument
EN:
Jn*:
Un*:
n1:
n2:
n3:
Output argument
ENO:
d1:
d2:
Function
This instruction writes clock data to a CPU module on another station.
5.4 CC-Link IE Controller Network, MELSECNET/H, and Ethernet Instruction
5-132
5.4.13 RTMWR instruction
Z_RTMWR_U
EN
ENO
ENO:=
Z_RTMWR_J
Un*
d1
ENO:=
Z_RTMWR_U
n1
d2
n2
n3
Executing condition
Network number of the host station (1 to 239)
"
254: Network specified in
Valid module during other station
"
access
Start I/O number of the module
(00 to FE: Higher two digits when expressing the I/O number in
three digits)
Channel used by host station
Target station number
Target station's CPU type
Execution result
Variable that stores write clock data
Variable that turns ON upon completion of the instruction
d2[1] also turns ON at the time of error completion.
Internal device
Setting
*1
data
Bit
Word
n1
n2
n3
d1
d2
Z_RTMWR_J, Z_RTMWR_U
P: Executing condition
ST
instructions.
Z_RTMWR_J
Z_RTMWR_U
(EN, Jn*, n1, n2, n3, d1, d2);
(EN, Un*, n1, n2, n3, d1, d2);
:Bit
:String
:String
:ANY16
:ANY16
:ANY16
:Bit
:Array of ANY16 [0..4]
:Array of bit [0..1]
J
\
R, ZR
Bit
Word
*1: Local devices and file registers per program cannot be used as setting data.
:
indicates any of the following
ZP_RTMWR_J
ZP_RTMWR_U
Constant
Zn
U
\G
K, H
Others

Advertisement