Mitsubishi QJ71PB92V-U-HW User Manual
Mitsubishi QJ71PB92V-U-HW User Manual

Mitsubishi QJ71PB92V-U-HW User Manual

Profibus-dp master module

Advertisement

Thank you for purchasing the Mitsubishi programmable controller
MELSEC-Q series.
Prior to use, please read this and relevant manuals thorougly to fully
understand the product.
© 2005 MITSUBISHI ELECTRIC CORPORATION
PROFIBUS-DP
Master Module
MODEL
MODEL
CODE
IB(NA)-0800324-D(0808)MEE
User's Manual
(Hardware)
QJ71PB92V
QJ71PB92V-U-HW
13JP82

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi QJ71PB92V-U-HW

  • Page 1 PROFIBUS-DP Master Module User’s Manual (Hardware) QJ71PB92V Thank you for purchasing the Mitsubishi programmable controller MELSEC-Q series. Prior to use, please read this and relevant manuals thorougly to fully understand the product. MODEL QJ71PB92V-U-HW MODEL 13JP82 CODE IB(NA)-0800324-D(0808)MEE © 2005 MITSUBISHI ELECTRIC CORPORATION...
  • Page 2 SAFETY PRECAUTIONS (Always read these instructions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The instructions given in this manual are concerned with this product. For the safety instructions of the programmable controller system, please read the CPU module user’s manual.
  • Page 3 [Design Precautions] DANGER When a communication error occurs on PROFIBUS-DP, the status of the faulty station is as shown below. Create an interlock circuit in the sequence program using the communication status information to ensure the system operates safely (Input X1, buffer memory 5A20 to 5B19 (23072 to 23321)).
  • Page 4 [Design Precautions] DANGER When the QJ71PB92V is mounted in a redundant system, set the watchdog timer for DP-Slaves so that the calculation formula shown in PROFIBUS-DP Master Module User's Manual. If the formula is not satisfied, a watchdog timer error occurs in DP-Slaves during system switching. CAUTION Do not bunch PROFIBUS cables with the main circuit or power wires, or install them close to each other.
  • Page 5 [Installation Precautions] CAUTION Do not directly touch the module's conductive parts or electronic components. Touching the conductive parts could cause an operation failure or give damage to the module. [Wiring Precautions] DANGER Be sure to shut off all phases of the external power supply used by the system before wiring PROFIBUS cables.
  • Page 6 [Startup and Maintenance Precautions] DANGER Before cleaning, be sure to shut off all phases of the external power supply used by the system. Failure to do so may cause electrical shocks. CAUTION Do not disassemble or modify the module. Doing so could cause trouble, erroneous operation, injury, or fire. Use any radio communication device such as a cellular phone or a PHS phone more than 25cm (9.85 inch) away in all directions of the programmable controller.
  • Page 7 Voltage Directives, Section 3.1 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
  • Page 8 CONTENTS 1. Overview ......................1 2. Specification ....................2 3. Implementation and Installation ..............4 3.1 Handling precautions ................4 3.2 Installation environment ................5 4. Part Names and Settings ................6 5. Wiring ......................9 5.1 PROFIBUS cable wiring ................9 5.2 Wiring precautions .................
  • Page 9 (1) For programmable controller system To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to Chapter 9 "EMC AND LOW VOLTAGE DIRECTIVES"...
  • Page 10: Overview

    1. Overview This manual is provided for handling the QJ71PB92V PROFIBUS-DP master module (hereinafter referred to as "QJ71PB92V"). First, open the package of the QJ71PB92V and check that the following is included. Table 1.1 Packing List Model Product name Quantity QJ71PB92V QJ71PB92V PROFIBUS-DP master module...
  • Page 11: Specification

    2. Specification The performance specifications of the QJ71PB92V are given below. When using the QJ71PB92D-compatible function, refer to the PROFIBUS- DP Interface Module User's Manual. For the general specifications of the QJ71PB92V, refer to the QCPU User's Manual (Hardware Design, Maintenance and Inspection). Table 2.1 Performance specifications Item Specifications...
  • Page 12 (1) Transmission distance Table 2.2 Transmission distance Max. Transmission distance when Transmission speed Transmission distance repeater is used *1 9.6kbps 19.2kbps 1200m(3937ft.)/segment 4800m(15748ft.)/network 93.75kbps 187.5kbps 1000m(3281ft.)/segment 4000m(13123ft.)/network 500kbps 400m(1312ft.)/segment 1600m(5249ft.)/network 1.5Mbps 200m(656ft.)/segment 800m(2625ft.)/network 3Mbps 6Mbps 100m(328ft.)/segment 400m(1312ft.)/network 12Mbps *1 The max. transmission distance in the table above is based on the case where 3 repeaters are used.
  • Page 13: Implementation And Installation

    3. Implementation and Installation This section provides the handling precautions, from unpacking to installation of the QJ71PB92V. For details on implementation and installation of the QJ71PB92V, refer to the "QCPU User's Manual (Hardware Design, Maintenance and Inspection)." 3.1 Handling precautions The following are precautions for handling the QJ71PB92V as a unit.
  • Page 14: Installation Environment

    3.2 Installation environment Refer to the QCPU User's Manual (Hardware Design, Maintenance and Inspection).
  • Page 15: Part Names And Settings

    4. Part Names and Settings This section explains the names and settings of each part of the QJ71PB92V. Figure 4.1 QJ71PB92V appearance Table 4.1 Names of part Name Description These LEDs indicate the operation Indicator LEDs status of the QJ71PB92V. For details, refer to (1) in this chapter.
  • Page 16 (1) Indicator LEDs Figure 4.2 Indicator LEDs Table 4.2 Indicator LEDs Status Description Normally operating Hardware error (watchdog timer error) or power failure Exchanging I/O data*1 or during acyclic communications *2 Flashing SD/RD Not communicating with DP-Slave, or being in the standby system Ready to communicate or communication being performed...
  • Page 17 *1 The LED flashes at intervals based on the value set in "Data control time" in Master Parameters. *2 The LED flashes at the time of request or response in acyclic communication. *3 The LED status during token passing varies depending on the number of DP- Masters within the same network and the transmission speed setting, as shown the Table 4.3.
  • Page 18: Wiring

    5. Wiring 5.1 PROFIBUS cable wiring The following describes the pin assignments of the PROFIBUS interface connector on the QJ71PB92V, the PROFIBUS cable wiring specifications, bus terminator and other information. (1) Pin assignments of the PROFIBUS interface connector The following shows the pin assignments of the PROFIBUS interface connector (D-sub 9-pin female connector).
  • Page 19 (2) PROFIBUS cable The following shows the PROFIBUS cable and wiring specifications. (a) PROFIBUS cable Use a PROFIBUS cable that meets the following specifications (Type A (IEC 61158-2) compliant). Table 5.2 PROFIBUS cable specifications Item Transmission line Applicable cable Shielded twisted pair cable Impedance 135 to 165 (f = 3 to 20MHz) Capacity...
  • Page 20 (4) Wiring specifications for bus terminator When the QJ71PB92V is a terminal station, use a connector with built-in bus terminator that meets the following wiring specifications. VP (6) , min1/4W RxD/TxD-P (3) , min1/4W RxD/TxD-N (8) , min1/4W DGND (5) Figure 5.3 Wiring specifications for bus terminator (5) PROFIBUS equipment The PROFIBUS cables, connectors and other PROFIBUS...
  • Page 21: Wiring Precautions

    5.2 Wiring precautions As one of the requirements to give full play to QJ71PB92V’s functions and make up the system with high reliability, it is necessary to have an external wiring unsusceptible to an influence of noise. The following gives the precautions for external wiring of the QJ71PB92V.
  • Page 22: Setting From Gx Developer

    6. Setting from GX Developer In the intelligent function module switch setting, set the redundant system support function or QJ71PB92D-compatible function of the QJ71PB92V. The following setting should be made only when using the redundant system support function or QJ71PB92D-compatible function. When setting the intelligent function module switch, select either (1) or (2) shown below.
  • Page 23: External Dimensions

    7. External Dimensions 27.4(1.08) 4(0.16) 90(3.54) Unit : mm(inch) Figure 7.1 External dimensions Company names and product names used in this document are trademarks or registered trademarks of respective owners.
  • Page 24 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi;...