(4) Q64AD-GH
Device
Item
System area
[0]
S
Completion status
[1]
S
Pass data classification setting
[2]
S
System area
[3]
S
CH1 Industrial shipment settings offset value (L)
[4]
S
CH1 Industrial shipment settings offset value (H)
[5]
S
CH1 Industrial shipment settings gain value (L)
[6]
S
CH1 Industrial shipment settings gain value (H)
[7]
S
CH2 Industrial shipment settings offset value (L)
[8]
S
CH2 Industrial shipment settings offset value (H)
[9]
S
CH2 Industrial shipment settings gain value (L)
[10]
S
CH2 Industrial shipment settings gain value (H)
[11]
S
CH3 Industrial shipment settings offset value (L)
[12]
S
CH3 Industrial shipment settings offset value (H)
[13]
S
CH3 Industrial shipment settings gain value (L)
[14]
S
CH3 Industrial shipment settings gain value (H)
[15]
S
CH4 Industrial shipment settings offset value (L)
[16]
S
CH4 Industrial shipment settings offset value (H)
[17]
S
CH4 Industrial shipment settings gain value (L)
[18]
S
CH4 Industrial shipment settings gain value (H)
[19]
S
CH1 User range settings offset value (L)
[20]
S
CH1 User range settings offset value (H)
[21]
S
CH1 User range settings gain value (L)
[22]
S
CH1 User range settings gain value (H)
[23]
S
CH2 User range settings offset value (L)
[24]
S
CH2 User range settings offset value (H)
[25]
S
CH2 User range settings gain value (L)
[26]
S
CH2 User range settings gain value (H)
[27]
S
CH3 User range settings offset value (L)
[28]
S
CH3 User range settings offset value (H)
[29]
S
CH3 User range settings gain value (L)
[30]
S
CH3 User range settings gain value (H)
[31]
S
CH4 User range settings offset value (L)
[32]
S
CH4 User range settings offset value (H)
[33]
S
CH4 User range settings gain value (L)
[34]
S
CH4 User range settings gain value (H)
[35]
S
Setting data
The instruction completion status is stored.
0
: Normal completion
Other than 0
: Error completion (error code)
The value set for pass data classification setting
by the OGLOAD instruction is stored.
0: Voltage specified
1: Current specified
b15
b4
b3
b2
b1
0
to
0
CH4 CH3 CH2 CH1
G_OGSTOR
Setting range
[2]
S
0000
to
H
0000F
H
b0
5.1 Analog Instruction
5.1.3 OGSTOR instruction
Setting side
System
System
System
System
System
System
System
5
System
System
System
System
System
System
System
System
System
System
System
5-31