4.4.2

Basic unit outputs

Description
SIMOCODE pro has a "BU Outputs" function block with two or three relay outputs. You can,
for example, switch contactors or lamps via these relay outputs. For this, the inputs (plugs) of
the function block must be connected to the respective sockets (usually the QE contactor
controls of the control function). The "BU Outputs" function block consists of:
● Three plugs corresponding to the relay outputs Out1 to Out3
● Three relays
● Output terminals.
In total, one function block "BU outputs" is available on the pro C, pro S, and pro V basic
units.
Schematic
The following schematics show the "BU Outputs" function block:
Figure 4-44
Figure 4-45
SIMOCODE pro - Parameterize
Operating Manual, 04/2017, A5E40507630002A/RS-AA/001
"BU Outputs" function block, SIMOCODE pro C, pro V, pro V
Function block "BU outputs," SIMOCODE pro S
Parameters
4.4 Outputs