Manual Pulse Generator Input Magnification (Numerator) [Bfm #525, #524, Bfm #625, #624]; Manual Pulse Generator Input Magnification (Denominator) [Bfm #527, #526, Bfm #627, #626] - Mitsubishi FX3U-20SSC-H User Manual

Melsec-f programmable controllers
Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
Notes on saving data into flash memory
• The save command is ignored during a positioning operation.
• Be sure to note the following points while saving data into the flash memory (status information: ON).
- Do not turn the power OFF while saving data into the flash memory.
- Do not write any data to buffer memories until saving data into flash memory is completed.
• A memory error occurs when failed to save data into the flash memory.
• The maximum number of times data can be written to the flash memory is 100,000 times.
The number of times data has been written to the flash memory can be checked by the number of writes.
Notes on initializing buffer memories
While initialization is in progress, the "initializing" status of the status information is ON and READY/BUSY is
OFF (BUSY).
11.4.16 Manual pulse generator input magnification (numerator)
[BFM #525, #524, BFM #625, #624]
This data item sets the magnification to be applied to the numerator of a pulse train input by the manual pulse
generator.
BFM Number
X-axis
BFM
BFM
#525,#524
#625,#624
11.4.17 Manual pulse generator input magnification (denominator)
[BFM #527, #526, BFM #627, #626]
This data item sets the magnification to the denominator of a pulse train input by the manual pulse generator.
BFM Number
X-axis
BFM
BFM
#527,#526
#627,#626
134
→ For details on the flash memory maximum number of writes, refer to Section 11.3.28
→ For details on the manual pulse generator, refer to Section 8.3
Y-axis
Setting range: 1 to 1,000,000 times
→ For details on the manual pulse generator, refer to Section 8.3
Y-axis
Setting range: 1 to 1,000,000 times
11 Buffer Memory (Parameters & Monitored Data)
Description
Description
11.4 Control Data
Default
K1
Default
K1