Liner Interpolation Operation - Mitsubishi FX3U-20SSC-H User Manual

Melsec-f programmable controllers
Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U
9.9

Liner Interpolation Operation

→ For details on the related parameters, control data, and monitor data, refer to Section 9.12
1. Operation
Y axis
1) Set operation speed 1 of X-axis and target address 1 of X/Y-axis.
2) Select the linear interpolation operation from the operation pattern of X-axis and activate the START
command of X-axis. The linear interpolation operation shown above will be started at vector speed
(X-axis operation speed 1). (The positioning completion signal is turned OFF.)
The operation pattern and START command of Y-axis are ignored.
3) The work piece stops at the XY coordinate in target address 1, and the operation ends, turning the
positioning completion signal ON.
POINT
• The positioning completion signal turns ON if the travel distance is 0.
If the travel distance is 0 or the travel time is too short, however, it is impossible for the sequence program
to detect the positioning completion signal turning OFF.
• When interpolation operation is continued in table operation, it is continuous pass operation.
2. Operation speed
Actual operation speed (vector speed) is "X-axis operation speed 1 x X-axis override setting."
Operation speed 1 of X-axis can be changed using the operation speed change function except for operating
under the following conditions.
• During deceleration operation
• When the speed change disable during operation signal is ON.
3. Address specification
Absolute/relative address can be specified.
With the specified absolute address: Specifies a target address (position) using address 0 as the base.
With the specified relative address: Specifies a travel amount from the current address.
4. Rotation Direction
With the specified absolute address: The rotation direction depends on whether the target address 1 is
With the specified relative address: The rotation direction is decided by the sign (positive/negative) of target
→ For details on the operation speed change, refer to Section 7.5
→ For details on torque limit, refer to Subsection 7.6.3
→ For details on STOP command, refer to Section 7.4
Speed
Target address 1
(X,Y axis)
X axis
OFF
START command
ON
Positioning completion
→ For details on the continuous pass operation, refer to Section 10.10
larger or smaller than the current address.
address 1.
9.9 Liner Interpolation Operation
Interpolation
time constant
Maximum speed
Vector speed
(operation speed 1
of X axis)
Target address 1
(X,Y axis)
ON
OFF
9 Positioning Control
1
2
Interpolation
time constant
3
4
Time
ON
5
6
7
8
9
10
85