Note
If the moving directions of target address 1 and target address 2 are not the same as follows, a reverse
operation is performed immediately after the deceleration stop at target address 1.
With the specified absolute address: when the sign difference between the current value and target address
1 is different from the sign difference between target address 1 and target address 2.
With the specified relative address : when the sign (positive/negative) of target address 1 differs from that of
target address 2.
Caution
An abrupt change of the rotation direction may damage the machine. It may also cause an error by motor
overload.
If the operation in a different direction requires stop time, use 1-speed positioning operation.