Error category
(decimal)
Parentheses ( ) in the error code column indicate the LED display on the servo amplifier.
Servo amplifier

13.2.4 Servo warning list [BFM #68 (X-axis), BFM #168 (Y-axis)]

The warning detected by the servo amplifier is stored.
Remove the cause of the warning.
1. State when a warning code occurs
Warning
Servo amplifier
code
LED indication
2102
2106
2116
2140
2141
2143
2144
2146
2147
2148
2149
2152
2153
160
Error
Code
Error Content
→For details on how to check errors and actions, refer to the manual of the servo amplifier to be connected.
Excessive error
The deviation between the model position and the
actual servo motor position exceeds the excessive
error alarm level (servo parameter) setting value
(default: 3 rotations).
2052
(52)
Motor combination error
2060
Wrong combination of servo amplifier and servo
(1A)
motor
2088
Watchdog
(888)
CPU/part fault
→ For details on warnings, refer to the manual of the servo amplifier to be connected.
92
Open battery cable warning
96
Home position setting warning
9F
Battery warning
E0
Excessive regenerative warning
E1
Overload warning 1
E3
Absolute position counter warning
E4
Parameter warning
E6
Servo forced stop warning
E7
Controller forced stop warning
E8
Cooling fan speed reduction warning
E9
Main circuit OFF warning
EC
Overload warning 2
ED
Output watt excess warning
→Refer to subsection 11.2.3
Name
13.2 Check Error Code
Action
Increase the acceleration/deceleration time
constant.
Increase the torque limit value.
The motor cannot be started due to insufficient
torque caused by a power supply voltage drop.
-
Review the power supply capacity.
-
Use a servo motor with larger output.
Increase the value of model control gain (servo
parameter) and adjust to ensure proper operation.
→Refer to subsection 11.2.2
The servo motor shaft was rotated by external
force.
-
When the torque is limited, increase the limit
value.
-
Reduce the load.
-
Use a servo motor with larger output.
Machine collision occurred.
-
Review the operation pattern.
-
Install limit switches.
Replace the servo motor.
Connect the servo motor correctly.
Replace the SSCNET III cable.
Select the correct combination.
The servo amplifier must be repaired. Consult a
Mitsubishi Electric distributor.
State when a warning occurs
Servo amplifier
Servo ON is
continued
Servo OFF
Servo ON is
continued
13 Diagnostics
20SSC-H
Operation is
continued
Operation is
continued
warning(zero return
completed: OFF)
Open battery cable
warning
Servo OFF
(An error has
occurred.)
Operation is
continued

Advertisement