10.4
Current Position Change
This operation information changes the current address (user/pulse) value to the one specified in the position
(address) information.
10.5
Absolute Address Specification
This operation information sets the position data of subsequent table operations to an absolute address
based on the (0, 0) point.
Note
• When table operation is started, the position information in handled on the absolute address specification
(default). To use position information by relative addresses, the operation information of positioning control
must be set beforehand.
• The arc center (i , j), radius r, Interrupt 1-speed constant quantity feed and, Interrupt 2-speed constant
quantity feed setting items are handled as relative addresses.
10.6
Relative address specification
This operation information sets the position data of subsequent table operations to a relative address based
on the current address.
Point
When table operation is started, the position information in handled on the absolute address specification
(default). To use position information by relative addresses, the operation information of positioning control
must be set beforehand.
10.7
Jump
When executing this operation information, jumps to the specified table No..
Note that table No. does not jump from X-axis table information to Y-axis table information.
Set the table No. of the jump point to the position information of the table information in buffer memory.
(On FX Configurator-FP, set the table No. of the jump point by the Jump No.)
10.8
Dwell
When executing this operation information, operation waits for the specified time. A dwell is used as a wait to
move between operations.
Set the dwell by the position information of the table information in the buffer memory.
(On FX Configurator-FP, set the dwell by the Time.)