Appendix A-2 Control Data Table - Mitsubishi FX3U-20SSC-H User Manual

Melsec-f programmable controllers
Hide thumbs Also See for FX3U-20SSC-H:
Table of Contents

Advertisement

FX
-20SSC-H Positioning Block User's Manual
3U

Appendix A-2 Control Data Table

BFM number
X axis
Y axis
BFM
BFM
Target address1
#501,#500
#601,#600
BFM
BFM
Operation speed1
#503,#502
#603,#602
BFM
BFM
Target address2
#505,504
#605,#604
BFM
BFM
Operation speed2
#507,#506
#607,#606
BFM #508
BFM #608
Override setting
Torque output setting
BFM #510
BFM #610
value
BFM
BFM
Speed change value
#513,#512
#613,#612
Target position
BFM
BFM
change value
#515,#514
#615,#614
(address)
Target position
BFM
BFM
change value
#517,#516
#617,#616
(speed)
BFM #518
BFM #618
Operation command 1
BFM #519
BFM #619
Operation command 2
Operation pattern
BFM #520
BFM #620
selection
Table operation start
BFM #521
BFM #621
number
Control command
BFM #522
enable/disable
166
Item
-2,147,483,648 to 2,147,483,647 (user unit)
-2,147,483,648 to 2,147,483,647 (user unit)
-2,147,483,648 to 2,147,483,647 (user unit)
-2,147,483,648 to 2,147,483,647 (user unit)
1 to 30000(×0.1%)
0 to 10000(×0.1%)
-2,147,483,648 to 2,147,483,647 (user unit)
-2,147,483,648 to 2,147,483,647 (user unit)
-2,147,483,648 to 2,147,483,647 (user unit)
b0
Error reset
b1
STOP (Deceleration stop)
b2
Forward rotation limit (LSF)
b3
Reverse rotation limit (LSR)
b4
Forward rotation JOG
b5
Reverse rotation JOG
b6
Mechanical zero return command
b7
Not available
b8
Relative/absolute address specification
b9
START command
b10 Simultaneous START flag
b11 m code OFF
b12 Change command in operation disabled
b13 Speed change command in positioning operation
b14 Target position change command in positioning operation
b15 Not available
b0
Remaining distance operation cancel command
b3 to b1 Not available
b4
Positioning parameter enable command
b7 to 5
Not available
b8
Servo OFF command
b9
Servo parameter transfer command
b10
Gain change command
b15 to 11 Not available
b0
1-speed positioning
b1
Interrupt 1-speed constant quantity feed
b2
2-speed positioning
b3
Interrupt 2-speed constant quantity feed
b4
Interrupt stop
b5
Variable speed operation
b6
Manual pulse generator operation
b7
Linear interpolation
b8
Linear interpolation (interrupt stop)
b9
Table operation (independent)
b10
Table operation (simultaneous)
b15 to 11 Not available
0 to 299
Model code: control command enabled
Other than model code: control command disabled
Appendix A: LIST OF PARAMETERS AND DATA
Description/Setting range
*1
*1
*1
*1
*1
*1
*1
Appendix A-2 Control Data Table
Default
Reference
value
K0
subsection 11.4.1
K1
subsection 11.4.2
K0
subsection 11.4.3
K1
subsection 11.4.4
K1000
subsection 11.4.5
K0
subsection 11.4.6
K1
subsection 11.4.7
K0
subsection 11.4.8
K0
subsection 11.4.9
H0000
subsection 11.4.10
H0000
subsection 11.4.11
H0000
subsection 11.4.12
K0
subsection 11.4.13
H0000
subsection 11.4.14